Solicitation
Triennial Circuit Breaker and Feeder Testing
Department of Veterans Affairs
SDVOSB set-aside · Reno, NV
AI summary Beta
This summary may miss requirements: 4 of 13 attachments weren't read (Reno Site Visit 11-05.pdf, Facility Floor Plan.pdf and 2 more). Check the attachments on SAM.gov.
The Department of Veterans Affairs' Network Contract Office 21 wants a firm to do the triennial (every three years) circuit breaker and feeder testing at the Reno VA Medical Center, 975 Kirman Ave, Reno, Nevada, under solicitation 36C26127Q0067. Only certified service-disabled veteran-owned small businesses (SDVOSBs) can bid, and award is on price alone for one firm-fixed-price (FFP: one set price, whatever the work ends up costing) job. The response due date is December 4, 2026, 12:00 PM PST, by email to alex.arter@va.gov.
Who can bid (7)
- Total SDVOSB set-aside: you must be a certified SDVOSB in SBA's Veteran Small Business Certification when you send your quote From 36C26127Q0067 0002.docx
- Signed certificate that you'll keep to the 75 percent limit on paying firms that aren't similarly situated (special trade contractors) From 36C26127Q0067_1.docx
- At least five continuous years of experience testing electrical power distribution systems, checked as responsibility after quotes From 36C26127Q0067 0002.docx
Show all 7Show fewer
- All technicians certified by the International Electrical Testing Association (NETA) or equivalent, with OSHA 10-hour construction safety training From 36C26127Q0067_1.docx
- Superintendent with OSHA 30-hour certification From 36C26127Q0067_1.docx
- A professional engineer to seal the coordination study and arc flash analysis; a Nevada license isn't required From 36C26127Q0067 0002.docx
- All certifications and licenses that local, state and federal rules require for this work From 36C26127Q0067_1.docx
How to submit: Email to alex.arter@va.gov. What to include is under Full summary below. Check the solicitation's instructions on SAM.gov.
Things to watch (8)
From the version posted Nov 20, 2026.
- Serious: Certified SDVOSBs only. Only businesses certified as service-disabled veteran-owned small businesses by SBA when they quote can bid. From 36C26127Q0067_1.docx
- Serious: Subcontracting certificate required. A quote without the signed VAAR 852.219-75 certificate is ineligible, and you may pay non-similarly-situated subcontractors no more than 75 percent of the contract amount, excluding materials. From 36C26127Q0067_1.docx
- Worth checking: You do the 25KV switching. The winner switches the medium-voltage system under the electrical supervisor's authority, so you need crews qualified for 25KV work. From 36C26127Q0067 0002.docx
Show all 8Show fewer
- Worth checking: Professional engineer seal needed. The coordination study and arc flash analysis must be sealed by a professional engineer, so line one up on staff or as a subcontractor. From 36C26127Q0067 0002.docx
- Worth checking: Night and weekend testing. Testing runs 6 PM to 6 AM, on weekends and holidays, including a facility-wide Saturday medium-voltage outage, which raises labor costs. From 36C26127Q0067 0002.docx
- Worth checking: Equipment counts are from earlier tests. The 477 breakers, 570 feeders and other counts come from previous tests, and the color-coded one-lines that set the scope were only partly readable here. From 36C26127Q0067 0002.docx
- Minor: No new questions accepted. Amendment 0005 closed questions (requests for information, RFIs), so price from the posted answers and drawings. From 36C26127Q0067 0005.docx
- Minor: Final report due 7 days after testing. The full report with test data, photos and cost estimates is due within 7 days of finishing testing. From 36C26127Q0067_1.docx
Read from the notice and 9 attachments. 4 of 13 not read. Show which files.
- 36C26127Q0067 0005.docx (read)
- 36C26127Q0067 0004.docx (read)
- 36C26127Q0067 0003.docx (read)
- 36C26127Q0067 0002.docx (read)
- 36C26127Q0067 0001.docx (read)
- 36C26127Q0067_1.docx (read)
- C27 - Single-Line Schematics.pdf (read)
- Attachment F- Plans and diagrams REVISED 11-13-23.pdf (read)
- Facility Single Line Diagram.pdf (read)
- Reno Site Visit 11-05.pdf: not summarized: open it on SAM.gov
- Facility Floor Plan.pdf: not summarized: open it on SAM.gov
- D1014-8 C03 36C26124P0555_TESTING REPORT.pdf: not read (it couldn't be opened): open it on SAM.gov
- Wage Determination 2015-5595 Washoe County.pdf: not summarized: open it on SAM.gov
Full summary
What they want
- Test the electrical distribution system to the ANSI/NETA maintenance testing standard (MTS) and VHA Directive 1028; past tests counted 11 MV switches, 10 MV transformers, 477 circuit breakers, 570 feeder cables and 27 LV transformers
- Very low frequency (VLF) testing of medium-voltage (MV) cable from vault to vault, inspecting and photographing every vault
- Test and exercise all 225-amp, 3-pole circuit breakers and above; torque connections, megger low-voltage feeders, clean connections and label tested equipment
- Do the medium-voltage (25KV) switching yourself; electrical testing happens off hours (6 PM to 6 AM, weekends, holidays), with outages set with the contracting officer's representative (COR) 2 weeks ahead
- Standard and infrared photographs of every item tested, as JPEG files under 4MB each
- Overcurrent protective device coordination study and arc flash analysis sealed by a professional engineer, with updated color-coded one-line diagrams in PDF and CAD and new engraved arc-flash labels
- Final report in PDF within 7 days of testing, with repair cost estimates and a separate estimate for replacing all MV cabling
- Include facilities added since 2017 (the new parking garage) and the Building 1D TN-LBSW branch
- Contract type
- Firm-fixed-price, one job (1.00 JB on the price schedule)
- Period of performance
- Not stated; work starts as soon as possible after the notice to proceed, and the VA's recommended test sequence runs 11 days plus extra days for new facilities
- Place of performance
- Reno VA Medical Center (VA Sierra Nevada Health Care System), 975 Kirman Ave, Reno, NV 89502
- Estimated value
- Not stated
- How they'll choose
- Price only, among responsible bidders; the 5-year experience requirement is checked as a responsibility matter after quotes, not scored
- Offers due
- December 4, 2026, 12:00 PM PST
- How to submit
- Email to alex.arter@va.gov
What they'll judge offers on
- Price
What to include when you submit
- Price the single line item on the B.2 price schedule
- Sign Standard Form 1449 (SF 1449) Block 30 if required: the form you sign and return as your offer
- Acknowledge Amendments 0001 through 0005
- Sign and return the VA limitations-on-subcontracting certificate (VAAR 852.219-75); quotes without it aren't considered
- Include proof of your SDVOSB certification status
- Complete the 52.212-3 representations if they aren't in your SAM.gov registration
- Split emails over 20MB into several messages
- Hold prices firm for 60 calendar days after the response due date
After award, you must have
- NFPA 70E qualified-person training certificates for each technician, sent to the contracting officer before work From 36C26127Q0067_1.docx:
Training certifications shall be submitted to the VA Contracting Officer before work.
Current contractor
No incumbent is named. The attached 2024 testing report carries contract number 36C26124P0555, and the answers mention a previous vendor that had an engineer on staff.
Not in the notice text
- The middle of the solicitation (about 59,000 characters, including the C.2 supplemental insurance requirements) wasn't read here, nor the 2024 testing report, the site-visit log, the floor plan or the wage determination; check them on SAM.gov
- Wage determination 2015-5595 (Washoe County) is attached but couldn't be read here; the documents don't say whether a Davis-Bacon wage determination applies to this NAICS 238210 work
- Exact equipment counts per building: the color-coded one-lines and single-line diagrams were only partly readable here
- Insurance amounts required
- Which existing drawings, CAD files and study models the VA will furnish
- Completion date or overall period of performance
- No estimated value or budget is given
More to check before you bid
- Not certified through VetCert yet? Apply on VetCert (SBA), or start with the SDVOSB guide. More open service-disabled veteran-owned set-asides under NAICS 238210
Notice details
Notice type, codes, versions and files
- Posted
- Nov 20, 2026
- Notice type
- Solicitation
- Office
- 261-Network Contract Office 21 (36C261), Mather, CA
- Product/service code
- J061 · Maint/Repair/Rebuild of Equipment – Electric Wire and Power Distribution Equipment
- Business type
- Construction & renovation (FedReady's grouping, from NAICS 238210)
- Versions
17 versions have been posted, newest first.
- Nov 20, 2026 · Amendment 0015 (this version)Due Dec 4, 2026
- Nov 19, 2026 · Amendment 0014Due Dec 4, 2026 (changed)
- Nov 6, 2026 · Amendment 0013Due Nov 20, 2026
- Nov 6, 2026 · Amendment 0012Due Nov 20, 2026
- Nov 6, 2026 · Amendment 0011Due Nov 20, 2026
- Nov 2, 2026 · Amendment 0010Due Nov 20, 2026
- Nov 2, 2026 · Amendment 0009Due Nov 20, 2026
- Nov 2, 2026 · Amendment 0008Due Nov 20, 2026
- Oct 23, 2026 · Amendment 0007Due Nov 20, 2026
- Oct 23, 2026 · Amendment 0006Due Nov 20, 2026
- Oct 23, 2026 · Amendment 0005Due Nov 20, 2026 (changed)
- Oct 19, 2026 · Amendment 0004Due Nov 9, 2026
- Oct 15, 2026 · Amendment 0003Due Nov 9, 2026
- Oct 14, 2026 · Amendment 0002Due Nov 9, 2026
- Oct 9, 2026 · Amendment 0001Due Nov 9, 2026
- Oct 9, 2026 · SolicitationDue Nov 9, 2026 (changed)
- Sep 25, 2026 · Sources SoughtDue Oct 2, 2026
- Attachments
Before you respond
- How to respond to a solicitation (8 steps)
- How to read a government solicitation
- How to price a government contract
- Open SDVOSB set-aside contracts
Terms on this notice: Solicitation, SDVOSB (service-disabled veteran-owned small business), Set-aside
Full notice text from SAM.gov
Similar open opportunities
- TVHS Generator PM/Bank Testing Base+4The Department of Veterans Affairs (VA), Network Contracting Office 9, wants yearly preventive maintenance and load bank testing (running each generator against a test load) on…
- LEX Triannual Energy Study and ARC Flash TestingOnly Service-Disabled Veteran-Owned Small Business (SDVOSB) firms can bid.
- WTX Elevator Inspections and Load Testing Services - Amended
- Supply, Installation, Testing, and Commissioning of Audiovisual Systems for the Multi-Purpose Room and Executive Conference Room at the U.S. Embassy in Malé, MaldivesThe U.S. Embassy in Colombo, Sri Lanka, wants a turnkey audiovisual system (equipment, installation, programming, testing, commissioning and training) for two rooms at the U.S.…