Solicitation
Annual/Sem-i annual fire smoke inspections and auto door services l EKH
Department of Veterans Affairs
Small business set-aside · KS
AI summary Beta
The notice looks incomplete: Attached but not read in full: 36C25526Q0617 Fire Smoke Auto Door IDIQ RFQ.pdf, 36C25526Q0617 0003.pdf and 36C25526Q0617 Amendment 0002.pdf (the middle of each was left out). The statement of work details, quote instructions, evaluation factors, wage determination and insurance terms may be there. Check the attachments on SAM.gov.
Solicitation 36C25526Q0617: Department of Veterans Affairs Network Contracting Office 15 wants twice-a-year fire, smoke and automatic door inspections, plus repairs, at the Dwight D. Eisenhower VA Medical Center in Leavenworth, Kansas. Only small businesses under NAICS 541350 can quote (total small business set-aside). The response due date is November 27, 2026, 3:00 PM Central, by email. It is a single-award, firm-fixed-price (one set price per unit) indefinite-delivery, indefinite-quantity (IDIQ: as-needed orders up to a ceiling) contract for five 12-month ordering periods.
Who can bid (6)
- Small business under NAICS 541350 (size standard $11.5 million): only small businesses can quote From 36C25526Q0617 Fire Smoke Auto Door IDIQ RFQ.pdf
- Active registration in SAM.gov at the time of the offer From 36C25526Q0617 Fire Smoke Auto Door IDIQ RFQ.pdf
- Limitations on subcontracting (FAR 52.219-14): the small business prime must perform a share of the work itself; subcontract work counts only if the subcontractor is similarly situated From 36C25526Q0617 Amendment 0002.pdf
Show all 6Show fewer
- Current AAADM (American Association of Automatic Door Manufacturers) certification for all automatic door technicians, with credentials sent with the quote From 36C25526Q0617 0003.pdf
- Fire door inspector qualifications for the people doing the work: DHI FDAI (Door and Hardware Institute Fire Door Assembly Inspector), ICC (International Code Council) or equivalent; VA is still deciding whether an NFPA course certificate counts From 36C25526Q0617 0003.pdf
- Relevant past performance, including that of a proposed subcontractor doing a meaningful part of the work From 36C25526Q0617 0003.pdf
How to submit: Email to michael.murphy7@va.gov. What to include is under Full summary below. Check the solicitation's instructions on SAM.gov.
Things to watch (13)
From the version posted Nov 18, 2026.
- Serious: Total small business set-aside. Only small businesses can quote, and the limitations on subcontracting clause (FAR 52.219-14) limits how much work can go to subcontractors. From 36C25526Q0617 Fire Smoke Auto Door IDIQ RFQ.pdf
- Serious: Technician names and credentials due with the quote. A quote must name technicians and include their current AAADM and fire door inspector credentials, so a bidder must have qualified people lined up before it quotes. From 36C25526Q0617 0003.pdf
- Worth checking: Subcontractor details needed in the quote. Each planned subcontractor, its size status, its work and its share of the amount paid must be listed; a general promise is not enough. From 36C25526Q0617 0003.pdf
Show all 13Show fewer
- Worth checking: Pricing questions left open. VA has not settled the containment pricing, the local hard-barrier exception or whether an NFPA certificate counts as a fire door inspector qualification, which can change a bidder's price and staffing. From 36C25526Q0617 Amendment P05.pdf
- Worth checking: Hospital infection-control containment. The contractor must furnish containment barriers, and Level III and IV work needs critical barriers, negative air and permits, so costs vary by area. From 36C25526Q0617 Amendment P05.pdf
- Worth checking: Wage determination revision not settled. The solicitation cites wage determination 2015-5105 Revision 27, and a later revision exists for the same counties; VA says a later amendment will identify which applies. From 36C25526Q0617 0003.pdf
- Worth checking: Personnel vetting before work. Technicians cannot work until required vetting is complete, which can delay the first inspection round. From 36C25526Q0617 0003.pdf
- Worth checking: Fully burdened prices, no travel or mobilization pay. Prices must cover travel, tools, reports and tags; VA pays no separate trip, travel or mobilization charges. From 36C25526Q0617 0003.pdf
- Worth checking: Only a $2,500 minimum is guaranteed. Quantities are estimates; VA need not order more than the guaranteed minimum. From 36C25526Q0617 Fire Smoke Auto Door IDIQ RFQ.pdf
- Worth checking: Fast emergency response, any hour. Life-safety emergencies need a technician on site within four hours at any time of day, with a 24 hour phone line. From 36C25526Q0617 0003.pdf
- Worth checking: Inspections paid only after the full round report is accepted. Each semiannual round is invoiced once VA accepts the full report, which can delay payment. From 36C25526Q0617 0003.pdf
- Minor: First inspection round timing. The first round must begin within 30 calendar days after award and finish within 60 calendar days after award. From 36C25526Q0617 0003.pdf
- Minor: Asbestos not covered. Asbestos assessment and removal are not in the contract; suspect material means stopping work and calling the COR (contracting officer's representative). From 36C25526Q0617 0003.pdf
Read from the notice and 6 attachments. Show which files.
- 36C25526Q0617 Fire Smoke Auto Door IDIQ RFQ.pdf (read)
- 36C25526Q0617 Amendment P05.pdf (read)
- 36C25526Q0617 Amendment 0004.pdf (read)
- 36C25526Q0617 0003.pdf (read)
- 36C25526Q0617 Amendment 0002.pdf (read)
- 36C25526Q0617 Amendment 0001.pdf (read)
Full summary
What they want
- Inspect every manual fire and smoke door assembly twice per ordering period under NFPA 80/105 (fire door standards): 126 assemblies, 252 inspections per period, up from 248 in the original schedule
- Inspect and maintain automatic doors twice per period to AAADM and ANSI/BHMA standards: 57 doors, 114 inspections per period, with parts and labor for normal-wear malfunctions included in the unit price
- Service call and repair labor: estimated 200 HR at normal hours and 40 HR after hours, weekends and Federal holidays, per ordering period
- Keep a phone answered 24 hours a day; same-day on-site response for calls received by noon; a technician on site within 4 hours for life-safety emergencies
- Quote repairs from an itemized parts and labor quote; the Government's parts estimate is 1 LOT, $30,000.00 per ordering period, not to be changed
- Deliver the complete inspection report within 10 working days after the full semiannual round; install a permanent identification tag on each door during the first round
- Start the first inspection round within 30 calendar days after award and finish it no later than 60 calendar days after award, unless the task order says otherwise
- Work in an occupied hospital under infection control review, furnishing your own containment barriers
- Contract type
- Single-award, firm-fixed-price (fixed unit price) IDIQ with bulk-funded task orders
- Period of performance
- 5 years (60 months) from award: five 12-month ordering periods, no option years. The schedule's dates, November 1, 2026 through October 31, 2031, are estimates based on a November 1, 2026 award. The extension of services clause, FAR 52.217-8, is also evaluated
- Place of performance
- Dwight D. Eisenhower VA Medical Center, 4101 S. 4th St., Leavenworth, KS 66048-5014
- Estimated value
- Contract maximum: all task orders together shall not exceed $750,000.00 across all five ordering periods. Guaranteed minimum: $2,500.00 for the whole term
- Offers due
- November 27, 2026, 3:00 PM Central (written as CST in Amendment 0005)
- How to submit
- Email to michael.murphy7@va.gov
- Page limits
- Volume I, Technical Capability: 10 pages maximum, excluding cover page, table of contents, certificates and sample report. A cover letter with technical content counts. Past Performance is separate and does not count.
What they'll judge offers on
- Factor 1, technical capability: Volume I Technical Capability, including technician names, locations and copies of current AAADM and fire door inspector credentials, and a subcontractor list
- Factor 2, past performance: relevant past performance, including that of a proposed subcontractor doing a meaningful part of the work
- Price: total evaluated price is the sum of the extended prices of CLINs X001 to X004 plus the Government's $30,000 parts estimate once per period, plus one-half of the Ordering Period V total for the FAR 52.217-8 extension
What to include when you submit
- Price every contract line item number (CLIN: one priced line of the order) in every ordering period with a unit price and amount; leave the Government's $30,000 parts estimate (CLIN X005) unchanged
- Send technician names, locations and copies of current AAADM and fire door inspector credentials with the quote; they are not accepted after award
- List every planned subcontractor, the NAICS code for its subcontract, its size status under that code, the work it will do and its estimated share of the amount paid, and explain compliance with FAR 52.219-14 (limitations on subcontracting)
- A general statement that later subcontractors will be small is not enough; an executed subcontract is not required with the quote
- Past performance (separate from the 10 pages): if a subcontractor's experience is used, identify the subcontractor, its role and which references are its own
- Include a sample inspection report and certificates (they are outside the 10 page limit)
- Acknowledge Amendment 0005 and all earlier amendments with the quote, giving each number and date; a quote already sent may be revised before the response due date
- Fill in the SF 1449 (Standard Form 1449, the commercial offer form) offeror blocks, and the schedule prices fully burdened for labor, travel, tools, reports, insurance, overhead and profit
After award, you must have
- Technicians must finish required personnel vetting (background investigation and Personal Identity Verification card) before they work; an escort does not waive it From 36C25526Q0617 0003.pdf:
…does not waive vetting, fitness, credentialing or other applicable…
Current contractor
No incumbent contract has been identified in the records VA reviewed; facility staff did the most recent fire and smoke door inspection in-house, and prior repair contract numbers and pricing are not available. The 200 normal hours, 40 after-hours hours and $30,000 parts figures are Government estimates, not past spending. A draft of Amendment 0005 says DH PACE was the only company at the October 15, 2026 site visit.
Not in the notice text
- Attached but not read in full: 36C25526Q0617 Fire Smoke Auto Door IDIQ RFQ.pdf, 36C25526Q0617 0003.pdf and 36C25526Q0617 Amendment 0002.pdf (the middle of each was left out). The statement of work details, quote instructions, evaluation factors, wage determination and insurance terms may be there.
- How many past performance references to send and the evaluation method are not in the text read.
- Which wage determination revision applies, the completed federal equivalent rates and the final infection-control containment pricing are still deferred.
- Whether the attached Amendment 0005 is the final version; the file is marked as a draft.
- Work-area restrictions will be addressed at the time of award, and the conditions for temporary access while vetting is pending are not final.
- The historical inspection record and full door schedule details (leaf counts, ratings, operator models) are not provided.
Notice details
Notice type, codes, versions and files
- Posted
- Nov 18, 2026
- Notice type
- Solicitation
- Office
- 255-Network Contract Office 15 (36C255), Leavenworth, KS
- Product/service code
- H112 · Quality Control – Fire Control Equipment
- Business type
- Engineering, architecture & research (FedReady's grouping, from NAICS 541350)
- Versions
10 versions have been posted, newest first.
- Nov 18, 2026 · Amendment 0005 (this version)Due Nov 27, 2026 (changed)
- Nov 10, 2026 · AmendmentDue Nov 20, 2026
- Nov 10, 2026 · AmendmentDue Nov 20, 2026
- Nov 10, 2026 · AmendmentDue Nov 20, 2026 (changed)
- Nov 2, 2026 · AmendmentDue Nov 10, 2026
- Nov 2, 2026 · AmendmentDue Nov 10, 2026
- Oct 30, 2026 · AmendmentDue Nov 10, 2026 (changed)
- Oct 22, 2026 · AmendmentDue Nov 3, 2026
- Oct 21, 2026 · AmendmentDue Nov 3, 2026 (changed)
- Oct 7, 2026 · SolicitationDue Oct 23, 2026
- Attachments
Before you respond
- How to respond to a solicitation (8 steps)
- How to read a government solicitation
- How to price a government contract
- Set-aside contracts explained
Terms on this notice: Solicitation, Set-aside
Latest amendment note (Amendment 5) from SAM.gov
Similar open opportunities
- Fire Dampers Inspection and Testing ServicesSolicitation 36C25627Q0151: the Department of Veterans Affairs (Network Contracting Office 16) wants a business to inspect, test and report on 247 fire dampers (air-duct shutters…
- NTX Elevator Inspection - AmendmentThis is Amendment 0002 to solicitation 36C25727Q0031, an elevator inspection job for the Department of Veterans Affairs (Network Contracting Office 17) in Dallas, TX. Only…
- Boiler Controls Inspection and TestingOnly service-disabled veteran-owned small businesses (SDVOSBs) certified by the Small Business Administration (SBA) can quote on solicitation 36C25027Q0072, according to the…
- Government Publishing Office FY26 Equipment InspectionThe U.S. Government Publishing Office (GPO) wants a NETA-certified electrical testing company to inspect, test, calibrate and repair 148 electrical breakers and protective relays…
- 12847 - Flag, Fire Alarm and Signaling I