Solicitation
Government Publishing Office FY26 Equipment Inspection
United States Government Publishing Office
AI summary Beta
The U.S. Government Publishing Office (GPO) wants a NETA-certified electrical testing company to inspect, test, calibrate and repair 148 electrical breakers and protective relays at its Washington, DC campus. It plans a single firm-fixed-price purchase order awarded to the lowest-priced acceptable quote. The work must finish within 14 weeks.
Who can bid (5)
- NETA (InterNational Electrical Testing Association) certification to test breakers and apply certification stickers From SOW - Breakers and Relays - FY26 Equipment Inspection.pdf
- Certification sticker must come from a licensed and bonded vendor From SOW - Breakers and Relays - FY26 Equipment Inspection.pdf
- Inspector resumes showing at least five years of similar experience From 040ADV-26-Q-0002 - FY26 Electrical Equipment Inspection.pdf
Show all 5Show fewer
- Contractor must be USA-based and process all data in the U.S. From SOW - Breakers and Relays - FY26 Equipment Inspection.pdf
- No set-aside; open to all businesses. Active SAM.gov registration is expected for payment.
How to submit: Email to Contract Specialist Michael McKenzie (mrmckenzie@gpo.gov) and Contracting Officer Troy White (twhite@gpo.gov); no paper submissions, due The notice record shows Dec 15, 2026 5:00 PM Eastern, but the solicitation document says 5:00 pm EST on 15 December 2025 (see red flags). Questions were due 3 December 2025 per the document.. What to include is under Full summary below. Check the solicitation's instructions on SAM.gov.
Things to watch (5)
From the version posted Nov 20, 2025.
- Serious: NETA certification required. Only NETA-certified testers can bid, which rules out general electrical contractors without it. From SOW - Breakers and Relays - FY26 Equipment Inspection.pdf
- Worth checking: Lowest price wins. Award goes to the lowest priced acceptable quote, so margins can be thin and there is no credit for going beyond the minimum. From 040ADV-26-Q-0002 - FY26 Electrical Equipment Inspection.pdf
- Worth checking: Fixed price with unknown repair costs. Repairs are part of the fixed price, but major parts need Government approval first, so you must price conservatively for defective equipment you cannot see yet.
Show all 5Show fewer
- Minor: Contractor pays all travel costs. Travel, lodging, parking, meals and other expenses are not reimbursed, so they must be built into your price. From SOW - Breakers and Relays - FY26 Equipment Inspection.pdf
- Minor: Escorted access and limited hours. Work is limited to weekdays 7am to 3pm with escorts in line of sight, which can slow a 14-week schedule. From SOW - Breakers and Relays - FY26 Equipment Inspection.pdf
Read from the notice and 2 attachments. Show which files.
- 040ADV-26-Q-0002 - FY26 Electrical Equipment Inspection.pdf (read)
- SOW - Breakers and Relays - FY26 Equipment Inspection.pdf (read)
Full summary
What they want
- Inspect, test and calibrate 96 low-voltage circuit breakers (ABB, Siemens, Square D, GE) across several substations and a fire pump
- Inspect and test 26 medium-voltage (5kV and 15kV) circuit breakers and their 26 protective relays
- Make field repairs where possible (Government approval needed before ordering or replacing major parts)
- Set data points and trip settings per each manufacturer's guidelines, calibrate and return each breaker to full service
- Label each breaker with a two-year inspection certification sticker
- Send a Microsoft Excel status report every two weeks showing each breaker before and after testing
- Update existing one-line electrical drawings as required
- Contract type
- Firm-fixed-price purchase order (1 lot), commercial services, awarded on lowest price technically acceptable
- Period of performance
- Not to exceed 14 weeks
- Place of performance
- U.S. Government Publishing Office, 732 North Capitol St. NW, Building C, Room 127, Washington, DC 20401
- Estimated value
- Not stated
- How they'll choose
- Lowest Price Technically Acceptable (LPTA): lowest evaluated price among quotes rated Acceptable on Factor 1 and Satisfactory on Factor 2
- Offers due
- The notice record shows Dec 15, 2026 5:00 PM Eastern, but the solicitation document says 5:00 pm EST on 15 December 2025 (see red flags). Questions were due 3 December 2025 per the document.
- How to submit
- Email to Contract Specialist Michael McKenzie (mrmckenzie@gpo.gov) and Contracting Officer Troy White (twhite@gpo.gov); no paper submissions
What they'll judge offers on
- Factor 1: Technical and Management Approach (rated Acceptable or Unacceptable; needs inspector resumes and a timeline)
- Factor 2: Past Performance (rated Satisfactory or Unsatisfactory)
- Price (reasonableness check)
What to include when you submit
- Two parts: Technical Submission (Factor 1 and Factor 2) and Price
- Acceptable file formats are Word, Excel or PDF; no single email over 40MB; attachments unzipped
- Put solicitation number 040ADV-26-Q-0002 in the email subject
- Factor 1: overview of the solution, how you will manage the work, a timeline, and resumes for equipment inspectors showing at least five years of similar experience
- Factor 2: 3 to 5 relevant project summaries with agency name, points of contact, contract number, status, dollar value and type, and why it is relevant
- Fill in the contract line item (CLIN) price section; list any assumptions or exceptions
- Name a point of contact for the solicitation
- Hold prices firm for 90 days after the offer due date
- Late quotes will not be considered
Not in the notice text
- Which due date is correct (the document says December 15, 2025; the notice record says December 15, 2026)
- Estimated value or budget
- Start date or award timing
- Whether amendments exist (the notice says they will be posted under a separate notice)
More to check before you bid
- Service contracts usually set minimum pay rates (the Service Contract Act). Price the labor with the SCA price calculator.
Notice details
Notice type, codes, versions and files
- Posted
- Nov 20, 2025
- Notice type
- Solicitation
- Office
- Acquisition Services, Washington, DC
- Product/service code
- H361 · Inspection – Electric Wire and Power Distribution Equipment
- Business type
- Engineering, architecture & research (FedReady's grouping, from NAICS 541350)
- Attachments
Before you respond
- How to respond to a solicitation (8 steps)
- How to read a government solicitation
- How to price a government contract
Terms on this notice: Solicitation
Full notice text from SAM.gov
Similar open opportunities
- Fire Dampers Inspection and Testing ServicesSolicitation 36C25627Q0151: the Department of Veterans Affairs (Network Contracting Office 16) wants a business to inspect, test and report on 247 fire dampers (air-duct shutters…
- Boiler Controls Inspection and TestingOnly service-disabled veteran-owned small businesses (SDVOSBs) certified by the Small Business Administration (SBA) can quote on solicitation 36C25027Q0072, according to the…
- Annual/Sem-i annual fire smoke inspections and auto door services l EKHSolicitation 36C25526Q0617: Department of Veterans Affairs Network Contracting Office 15 wants twice-a-year fire, smoke and automatic door inspections, plus repairs, at the…
- NTX Elevator Inspection - AmendmentThis is Amendment 0002 to solicitation 36C25727Q0031, an elevator inspection job for the Department of Veterans Affairs (Network Contracting Office 17) in Dallas, TX. Only…
- 12847 - Flag, Fire Alarm and Signaling I