Combined Synopsis/Solicitation
TVHS Generator PM/Bank Testing Base+4
Department of Veterans Affairs
SDVOSB set-aside · Murfreesboro, TN
A newer version of this notice was posted Nov 17, 2026. See the latest version.
AI summary Beta
Summary of the version posted Nov 12, 2026. The notice was amended Nov 17, 2026. Check what else changed on SAM.gov.
Only Service-Disabled Veteran-Owned Small Businesses (SDVOSBs) can bid on solicitation 36C24927Q0027 from the Department of Veterans Affairs Network Contracting Office 9. It covers yearly preventive maintenance and load bank testing (running a generator against a test load) on 11 emergency generators and their fuel tanks at the Tennessee Valley Healthcare System, Alvin C. York campus, Murfreesboro, Tennessee. The contract is firm-fixed-price (FFP: one set price, whatever the work ends up costing), one base year from January 1, 2027 plus four one-year options. SAM.gov gives the response due date as December 9, 2026, 12:00 PM Central, but the notice text says November 19, 2026 (passed).
Who can bid (4)
- Be a Service-Disabled Veteran-Owned Small Business (SDVOSB) for this 100% set-aside; business size status is verified in the SBA's Small Business Search at quote submission and at award.
- Your SBA registration must include NAICS code 238210 to qualify as an SDVOSB for this size. From 36C24927Q0027.docx
- A complete System for Award Management (SAM) registration, including representations and certifications, when quotes are due.
Show all 4Show fewer
- Manufacturer-authorized service technicians with at least five years of experience on emergency generators, with proof of qualifications and certifications given before award; certifications must cover at least one manufacturer in the inventory. From 36C24927Q0027.docx
How to submit: Email to adrian.king@va.gov, as a PDF or Microsoft Word file (8 MB limit), with the subject "RFQ 36C24927Q0027 response"; confirm receipt with the contracting officer, due December 9, 2026, 12:00 PM Central (1:00 PM Eastern), as SAM.gov and the attached solicitation give it; the notice text says November 19, 2026, 12:00 PM CT. What to include is under Full summary below. Check the solicitation's instructions on SAM.gov.
Things to watch (10)
- Serious: Only SDVOSBs can bid. This is a 100% SDVOSB set-aside, so firms that are not Service-Disabled Veteran-Owned Small Businesses cannot compete.
- Serious: Two different response due dates. SAM.gov and the attached solicitation say December 9, 2026, 12:00 PM Central, but the notice text says quotes are due November 19, 2026 by 12:00 PM CT. Ask the contracting officer which date governs.
- Serious: Manufacturer-certified technicians required before award. You need technicians certified by at least one of the generator makers in the inventory (Cummins, Kohler, Generac, Caterpillar, John Deere, CK Power), with five years of experience. Proof is due before award. From 36C24927Q0027.docx
Show all 10Show fewer
- Worth checking: Fleet of six generator brands. Parts, fluids and procedures differ across the 11 units, and the contractor must check serial numbers and filter dates before servicing so the right parts are used. From 36C24927Q0027.docx
- Worth checking: Maintenance window is April each year. All load bank testing and PM are done in April, so crews and load banks must be available then each year, and the work must be scheduled 14 calendar days ahead. From 36C24927Q0027.docx
- Worth checking: Davis-Bacon wages likely apply (a general rule). This is the general rule, not something the notice says: federal construction over $2,000 in the U.S. pays at least the Davis-Bacon wage rates in the wage determination attached to the solicitation. This summary doesn't name one: find it on SAM.gov and price your labor from it.
- Minor: Overtime may be needed for load bank tests. Work is set for 7:00 am to 3:30 pm, but testing may run past normal hours, and the price is fixed. From 36C24927Q0027.docx
- Minor: Option 2 line 2008 shows 2028 dates. Line 2008 (Option 2) lists a performance period of January 1, 2028 to December 31, 2028, while the other Option 2 lines say 2029. Ask which is right. From 36C24927Q0027.docx
- Minor: Inventory brands differ between price lines and Attachment A. Line item 0009 says a Cummins generator at Bldg 116, while Attachment A lists John Deere at that building, and other lines differ in the same way. Check the units before pricing. From 36C24927Q0027.docx
- Minor: Questions were due Nov 23, 2026. Check the amendments for the agency's answers. From 36C24927Q0027.docx
Read from the notice and 1 attachment. Show which files.
- 36C24927Q0027.docx (read)
Full summary
What they want
- Annual preventive maintenance (PM) on 11 emergency generator sets in the inventory: engine oil and filters, all fuel filters, coolant filter, radiator exterior cleaning, and test of the antifreeze.
- Load bank testing of each generator: not less than 50% of the nameplate rating for 30 minutes, 75% for at least 1 hour, and 100% for at least 30 minutes, for at least 2 hours combined, then a cool-down run.
- A 4-hour load bank test every 36 months that uses the building's power plus a resistive load bank to reach 60-80% of the nameplate rating, listed as due in April 2026 and April 2029.
- Annual fuel samples and engine oil samples with lab analysis, and written reports in PDF form (Portable Document Format) with recorded test readings every 15 minutes.
- Battery replacement at 30-month anniversaries (October 2028 and April 2031), air filters as recommended or every three years, and 5-year cooling system service (belts, hoses, antifreeze, thermostats, gaskets, radiator caps) on the dates in Attachment C.
- Perform the work during April each year, Monday to Friday, 7:00 am to 3:30 pm, with the date set with the contracting officer's representative at least 14 calendar days ahead.
- Send reports to the contracting officer's representative within ten working days of finishing all load banks and PM work.
- Warrant all work, materials and equipment for one year from acceptance.
- Contract type
- Firm-fixed-price (FFP) service contract
- Period of performance
- Base year January 1, 2027 to December 31, 2027, plus four one-year options (through December 31, 2031); the work is done during April of each year
- Place of performance
- VA Tennessee Valley Healthcare System Murfreesboro, Alvin C. York Campus, 3400 Lebanon Road, Murfreesboro, TN 37129 (the statement of work says Lebanon Pike)
- Estimated value
- Not stated
- How they'll choose
- Lowest price technically acceptable (LPTA): the lowest-priced quote that is acceptable and price reasonable
- Offers due
- December 9, 2026, 12:00 PM Central (1:00 PM Eastern), as SAM.gov and the attached solicitation give it; the notice text says November 19, 2026, 12:00 PM CT (from the version posted Nov 12, 2026; amended since)
- How to submit
- Email to adrian.king@va.gov, as a PDF or Microsoft Word file (8 MB limit), with the subject "RFQ 36C24927Q0027 response"; confirm receipt with the contracting officer
What they'll judge offers on
- Technical
- Past Performance
- Price (including all option years, added to the base year)
What to include when you submit
- Submit only one quote; more than one quote from a company may get all of them rejected.
- Price each line item in the Price/Cost Schedule (11 generators in the base year and in each option year, each QTY 1.00 EA); you may use your own pricing document if it is broken down enough to judge lowest price.
- Put on the quote: RFQ number, contractor name and address, point of contact (name, title, phone, email) and SAM UEI (Unique Entity Identifier) number.
- State whether the RFQ terms and conditions are acceptable without change, or list your exceptions, deletions or additions.
- State that your offeror representations and certifications are complete in SAM.gov.
- List the amendments you received, by number and date; failing to acknowledge amendments may get the quote rejected.
Not in the notice text
- The Government's estimate is not stated.
- The notice text says instructions are on pages 7-9, while the attached solicitation says pages 20-21; the instructions in the attached solicitation are used here.
- The attached inventory (Attachment A) and the price lines don't fully match (for example the Bldg 116 and portable units), so which equipment is covered is unclear.
- The first 4-hour 36-month load bank test is listed as due in April 2026 and April 2029; the documents don't say whether one is due in the base year.
- Whether there's a site visit: this summary doesn't say. Check the solicitation and its amendments on SAM.gov.
More to check before you bid
- Not certified through VetCert yet? Apply on VetCert (SBA), or start with the SDVOSB guide. More open service-disabled veteran-owned set-asides under NAICS 238210
Notice details
Notice type, codes, versions and files
- Posted
- Nov 12, 2026
- Notice type
- Combined Synopsis/Solicitation
- Office
- 249-Network Contract Office 9 (36C249), Murfreesboro, TN
- Product/service code
- J061 · Maint/Repair/Rebuild of Equipment – Electric Wire and Power Distribution Equipment
- Business type
- Construction & renovation (FedReady's grouping, from NAICS 238210)
- Versions
2 versions have been posted, newest first.
- Nov 17, 2026 · Amendment 0001Due Dec 9, 2026
- Nov 12, 2026 · Combined Synopsis/Solicitation (this version)Due Dec 9, 2026
- Attachments
Before you respond
- How to respond to a solicitation (8 steps)
- How to read a government solicitation
- How to price a government contract
- Open SDVOSB set-aside contracts
Terms on this notice: Solicitation, SDVOSB (service-disabled veteran-owned small business), Set-aside
Full notice text from SAM.gov
Similar open opportunities
- Triennial Circuit Breaker and Feeder TestingThe Department of Veterans Affairs' Network Contract Office 21 wants a firm to do the triennial (every three years) circuit breaker and feeder testing at the Reno VA Medical…
- LEX Triannual Energy Study and ARC Flash TestingOnly Service-Disabled Veteran-Owned Small Business (SDVOSB) firms can bid.
- Install Generator- FCI BastropThe Federal Bureau of Prisons wants a firm-fixed-price (FFP: one set price, whatever the work ends up costing) construction contract under solicitation 15BBNF27Q50100001 to…
- Generator Maintenance ServiceOnly service-disabled veteran-owned small businesses (SDVOSBs) certified by the Small Business Administration (SBA) can bid on solicitation 36C24627Q0138.
- FY27 NRM - EHRM Base 573-27-702-DB EHRM Generator Upgrades Design-Build - Gainesville VAMCThe Department of Veterans Affairs wants to hear from firms able to design and build an emergency power generator upgrade at the Malcom Randall VA Medical Center in Gainesville,…