Solicitation
Generator Maintenance Service
Department of Veterans Affairs
SDVOSB set-aside · Hampton, VA
AI summary Beta
Only service-disabled veteran-owned small businesses (SDVOSBs) certified by the Small Business Administration (SBA) can bid on solicitation 36C24627Q0138. The Department of Veterans Affairs, Network Contracting Office 6, wants maintenance, load bank testing and repairs on twelve (12) emergency generators at the Hampton VA Medical Center in Hampton, Virginia. The response due date is November 27, 2026, 11:00 AM Eastern, by email. Award is one firm-fixed-price (FFP: one set price, whatever the work costs) contract with a base period and two option periods.
Who can bid (5)
- Must be a service-disabled veteran-owned small business designated in SAM.gov as certified by the SBA; quotes from other businesses will not be considered From 36C24627Q0138.docx
- Maintenance and testing personnel must be qualified through the EGSA certification program, with copies of certifications sent with the quote From 36C24627Q0138.docx
- Active SAM.gov registration when the quote is sent and at award From 36C24627Q0138.docx
Show all 5Show fewer
- Signed certification that the contractor will not pay more than 50% of the amount the Government pays it to firms that are not certified SDVOSBs or veteran-owned small businesses (limitations on subcontracting) From 36C24627Q0138.docx
- Past performance: up to three relevant emergency generator maintenance contracts from the last five years From 36C24627Q0138.docx
How to submit: Email to Yanique.williamschin@va.gov. What to include is under Full summary below. Check the solicitation's instructions on SAM.gov.
Things to watch (9)
From the version posted Nov 19, 2026.
- Serious: Only SBA-certified SDVOSBs can bid. The notice is set aside for service-disabled veteran-owned small businesses; a business not designated as certified in SAM.gov will not be considered. From 36C24627Q0138.docx
- Serious: EGSA certification for all generator personnel. Copies of the Electrical Generating Systems Association certifications must go in with the quote, and quotes that skip required documents are rejected. From 36C24627Q0138.docx
- Serious: Subcontracting limit certification must be returned with the quote. At most 50% of the amount paid may go to firms that are not certified SDVOSBs or veteran-owned small businesses, and a missing signed certification makes the quote ineligible. From 36C24627Q0138.docx
Show all 9Show fewer
- Worth checking: 24/7 emergency callback and possible rental generator. Emergency service is unlimited, any hour; for repairs over four hours the contractor must coordinate and connect a rental generator (the Government pays the rental). From 36C24627Q0138.docx
- Worth checking: Emergency repair line item capped at $10,000. Parts and labor for emergency repairs are invoiced against a $10,000 line item per period and cannot go over without written approval from the Contracting Officer. From 36C24627Q0138.docx
- Worth checking: Interrupted load bank test must restart. A four-hour continuous test stopped for any reason, even an emergency, has to be repeated in full, which adds cost and time. From 36C24627Q0138.docx
- Worth checking: Underground fuel tank tightness testing and fluid disposal. Tank tightness tests follow NFPA 30 and used fluids must be disposed of per EPA rules with paperwork to the VA; check you can do or subcontract these. From 36C24627Q0138.docx
- Minor: Fixed visit schedule with 7-day notice and escorts. Quarterly visits fall in the second week of December, March, June and September, need 7 days' notice, and the crew is escorted by VA staff at all times. From 36C24627Q0138.docx
- Minor: Questions were due Nov 24, 2026. Check the amendments for the agency's answers. From 36C24627Q0138.docx
Read from the notice and 1 attachment. Show which files.
- 36C24627Q0138.docx (read)
Full summary
What they want
- Quarterly preventive maintenance inspections on twelve (12) generators (four inspections per period), in the second week of December, March, June and September
- At each visit: hot oil sample with lab analysis report, top up coolant and battery fluid, inspect and record findings
- June visit: replace all fluids and filters and dispose of them per EPA rules. September visit: fuel testing and underground fuel tank tightness testing
- One four-hour continuous load bank test on each of the twelve (12) generators in April 2027 (base period) and April 2029 (Option 2)
- Emergency repairs with callback service 24 hours a day, 7 days a week, with a $10,000 repair line item per period (NTE: not to exceed)
- Formal written report within 15 calendar days after each inspection or test
- Follow National Fire Protection Association (NFPA) standards 110 and 70B; VA staff escort the crew at all times
- Contract type
- Firm-fixed-price (FFP): the Government contemplates award of a Firm-Fixed-Price contract
- Period of performance
- Base period plus Option 1 and Option 2. Start and end dates are listed as TBD and the length of each period is not stated. Total including the extension option clause may not exceed three (3) years.
- Place of performance
- Hampton VA Medical Center, 100 Emancipation Drive, Hampton, VA 23667
- Estimated value
- Not stated
- How they'll choose
- Best value: the Government will award to the responsible quoter whose quote is most advantageous, considering technical capability, past performance and price
- Offers due
- November 27, 2026, 11:00 AM Eastern
- How to submit
- Email to Yanique.williamschin@va.gov
What they'll judge offers on
- Technical Capability: how well the proposed services meet or exceed the performance work statement (PWS: the document that describes the work); completeness and adequacy of the performance of services
- Past Performance: record of past performance, which may come from the contracting officer's knowledge, the Contractor Performance Assessment Reporting System (CPARS) or any other reasonable basis
- Price: fairness and reasonableness; total evaluated price is the sum of all line items including all options, plus six months of the last period's price for the extension option
What to include when you submit
- Send the quote on a separate document with company letterhead and a quote breakdown
- Include a completed, signed and dated Standard Form 1449 (SF 1449: the form you sign and return as your offer) with name, address, telephone number and Unique Entity Identifier (UEI)
- Technical proposal as a PDF file labeled Technical Proposal, with no pricing information
- Technical proposal must name any subcontractors proposed and address how they will be used
- Technical proposal must include copies of all applicable Electrical Generating Systems Association (EGSA) certifications for the maintenance and testing personnel
- Technical proposal must explain methods and rationale and how the work will be organized, staffed and managed
- Price quote filled in as the price schedule in section B.2 asks, with a price for each line item including options
- Past performance narrative: up to three (3) relevant contracts for emergency generator maintenance within the last five (5) years
- For each reference give contract number, tasks performed, location, dates, whether the quoter or a subcontractor performed it, whether prime or subcontractor, and a contact name, phone and email
- Return the signed VA limitations on subcontracting certification (VAAR 852.219-75) with the quote
- Have an active registration in SAM.gov (the federal contractor database) when the quote is sent and at award
Current contractor
No incumbent is named in the documents.
Not in the notice text
- Start and end dates and the length of the base period and each option period are listed as TBD
- The Government's estimated value is not given
- Whether a site visit is offered is not stated; contractors are told to inspect each site where services are performed
- The wage determination (No. 2015-4341, Revision 36) is on SAM.gov and was not read here; check wage rates there
- The list of generators (size, make, location) is not in the documents
More to check before you bid
- Not certified through VetCert yet? Apply on VetCert (SBA), or start with the SDVOSB guide. More open service-disabled veteran-owned set-asides under NAICS 238220
Notice details
Notice type, codes, versions and files
- Posted
- Nov 19, 2026
- Notice type
- Solicitation
- Office
- 246-Network Contracting Office 6 (36C246), Hampton, VA
- Product/service code
- J061 · Maint/Repair/Rebuild of Equipment – Electric Wire and Power Distribution Equipment
- Business type
- Construction & renovation (FedReady's grouping, from NAICS 238220)
- Versions
2 versions have been posted, newest first.
- Nov 19, 2026 · Solicitation (this version)Due Nov 27, 2026
- Nov 18, 2026 · PresolicitationDate Nov 27, 2026
- Attachments
Before you respond
- How to respond to a solicitation (8 steps)
- How to read a government solicitation
- How to price a government contract
- Open SDVOSB set-aside contracts
Terms on this notice: Solicitation, SDVOSB (service-disabled veteran-owned small business), Set-aside