Sources Sought
FY27 NRM - EHRM Base 573-27-702-DB EHRM Generator Upgrades Design-Build - Gainesville VAMC
Department of Veterans Affairs
Response due Dec 7, 2026 · Gainesville, FL
Market research, not a bid. Replying is free and tells Department of Veterans Affairs who could do this work. Send a short reply to the contracting contact; no price is needed. See the contact
AI summary Beta
The Department of Veterans Affairs wants to hear from firms able to design and build an emergency power generator upgrade at the Malcom Randall VA Medical Center in Gainesville, Florida. This is a sources sought notice, market research only, not a solicitation. Capability statements are due December 7, 2026, 2:00 PM ET; any later buy would be a two-phase design-build, firm-fixed-price (FFP: one set price) contract.
Who can bid
- Available bonding capacity shown by a letter of intent from the bonding company, in line with the magnitude of construction
- Design-build or similar past projects completed in the last ten years, up to three from the design-build team and up to three from the designer
How to submit: Email to the primary and secondary points of contact; no phone calls and no hard copies. What to include is under Full summary below. Check the solicitation's instructions on SAM.gov.
Things to watch (5)
From the version posted Nov 23, 2026.
- Serious: Two-phase design-build selection planned. The later buy would use two-phase selection, so a business not advanced in the first phase may be shut out; no dates are given for the phases.
- Worth checking: Sources sought, not a solicitation. This is market research; the set-aside, if any, depends on the responses, and no solicitation exists yet.
- Worth checking: Bonding capacity letter needed with the response. A letter of intent from a bonding company is required with the capability statement.
Show all 5Show fewer
- Minor: Planned advertising date reads mid-January 2026. The notice gives the planned advertising as mid-January 2026, a year before the response due date; the year may be a typo, so ask the contracting office.
- Minor: Magnitude of construction figure is mistyped. The range is written as $5,000.000.00 to $10,000,000.00; confirm the lower figure.
Read from the notice text only.
Full summary
What they want
- Design and build a replacement emergency generator rated at not less than 2,000 kW for Electronic Health Record Modernization (EHRM)
- Provide all design, construction, permits, demolition, testing, commissioning, training and documentation
- Keep hospital emergency power working during construction, apart from approved planned switching windows
- Provide the enclosed generator with fuel, exhaust, switchgear interface, automatic transfer switch (ATS), distribution, monitoring, platform and site work, plus temporary emergency power
- Confirm the usable footprint, since expansion north or south of the existing site is not expected to be feasible
- Contract type
- Competitive firm-fixed-price design-build contract, planned, using two-phase design-build selection procedures
- Period of performance
- About 730 calendar days from the issuance of a Notice to Proceed
- Place of performance
- Gainesville, FL
- Estimated value
- Magnitude of construction: between $5,000.000.00 and $10,000,000.00 (as written in the notice)
- Offers due
- December 7, 2026, 2:00 PM ET
- How to submit
- Email to the primary and secondary points of contact; no phone calls and no hard copies
- Page limits
- Capability statement: no more than 12 single-sided pages, single-spaced, 12-point font minimum
What to include when you submit
- Send one application-generated (not scanned) PDF no larger than 4MB
- Include a cover page with company name, address, Unique Entity Identifier (if available), socio-economic status, point-of-contact name, phone number and email
- Put the Sources Sought number and project title in the email subject line
- Section 1: company name, DUNS number and UEI, address, point of contact
- Section 2: business size under NAICS 238210 and business type
- Section 3: a statement of interest in the project
- Section 4: the prime contractor's available bonding capacity, as a letter of intent from the bonding company
- Section 5: up to three design-build projects completed in the last ten years where the design-build team worked together, as a prime contractor managing multiple subcontractors
- A prime without design-build experience may give up to three relevant non-design-build projects in clinical, hospital or other medical space
- The designer may also give up to three relevant projects; no more than six projects in total
- Describe the self-performed effort in dollar value and description
Not in the notice text
- Whether there will be a site visit is not stated
- Whether a Davis-Bacon wage determination (the federal construction wage rule) applies is not stated
- The set-aside type, if any, will depend on the responses
- The email address of the secondary point of contact is not given in the text
- Dates for each phase of the later two-phase selection are not given
Notice details
Notice type, codes, versions and files
- Posted
- Nov 23, 2026
- Notice type
- Sources Sought
- Office
- Pcac (36C776), Independence, OH
- Product/service code
- Y1DA · Construction of Hospitals and Infirmaries
- Business type
- Construction & renovation (FedReady's grouping, from NAICS 238210)
- Attachments
Before you respond
Terms on this notice: Sources sought notice
Full notice text from SAM.gov
Similar open opportunities
- FY27 NRM - EHRM Base 509-22-701 - EHRM Infrastructure Upgrades - Downtown Division - Construction (VA-27-00011175)This is a sources sought notice, not a solicitation: the Department of Veterans Affairs (VA) is gathering information on general contractors for electronic health record (EHRM)…
- VISN 2 EHRM Industry Day
- Install Generator- FCI BastropThe Federal Bureau of Prisons wants a firm-fixed-price (FFP: one set price, whatever the work ends up costing) construction contract under solicitation 15BBNF27Q50100001 to…
- TVHS Generator PM/Bank Testing Base+4The Department of Veterans Affairs (VA), Network Contracting Office 9, wants yearly preventive maintenance and load bank testing (running each generator against a test load) on…
- Project620-22-110 Replace and Upgrade Fire alarm System at Montrose VAMCSolicitation 36C24227B0009_1: only certified service-disabled veteran-owned small businesses (SDVOSBs) can bid on this sealed-bid construction job (an invitation for bids, where…