Solicitation
Project620-22-110 Replace and Upgrade Fire alarm System at Montrose VAMC
Department of Veterans Affairs
AI summary says SDVOSB set-aside · NY
AI summary Beta
This summary may miss requirements: 3 of 8 attachments weren't read (620-22-110 Flash Badge Process Notification.doc, Fire Alarm Replacement Attachment A - Identification Card Process.doc and 1 more). Check the attachments on SAM.gov.
Solicitation 36C24227B0009_1: only certified service-disabled veteran-owned small businesses (SDVOSBs) can bid on this sealed-bid construction job (an invitation for bids, where bids are opened on the due day). The Department of Veterans Affairs, Network Contract Office 02, wants a campus-wide fire alarm system replaced at the VA Hudson Valley Health Care System, Montrose Campus, NY. Work takes 550 calendar days from notice to proceed. Bids are due December 22, 2026, 10:00 AM ET in the solicitation form, but SAM.gov lists December 16, 2026, 10:00 AM Eastern.
Who can bid (6)
- Service-disabled veteran-owned small business (SDVOSB): registered in SAM.gov with a UEI and verified or certified as an SDVOSB in the SBA Small Business Search when bidding and before award. This is a 100% set-aside. From 36C24227B0009 Fire Alarm Replacement.pdf
- Meet the size standard for NAICS 561621 (business size is $25 million). From 36C24227B0009 Fire Alarm Replacement.pdf
- Bid bond: copies of the original bid bond must be included with the bid. From 36C24227B0009 Fire Alarm Replacement.pdf
Show all 6Show fewer
- Fire alarm work done by licensed, factory-authorized fire alarm installation contractors or registered apprentices, who carry their license or registration on VA property. From Specifications-Final.pdf
- Fire alarm technicians at NICET Level 2 or higher, and journeyman or licensed electricians. From 36C24227B0009 Fire Alarm Replacement.pdf
- Limits on subcontracting: the certificate's marked box (special trade construction) says no more than 75% of the amount paid by the Government may go to firms that are not certified SDVOSBs or VOSBs. From 852.219-75 VA NOTICE OF LIMITATIONS ON SUBCONTRACTING-CERTIFICATE OF COMPLIANCE FOR SERVICES AND CONSTRUCTION.pdf
How to submit: Email only to Daniel.barone@va.gov. The bid opening is held online on Microsoft Teams on the due day., due December 22, 2026, 10:00 AM ET in the solicitation form; SAM.gov lists December 16, 2026, 10:00 AM Eastern. What to include is under Full summary below. Check the solicitation's instructions on SAM.gov.
Things to watch (10)
From the version posted Nov 17, 2026.
- Serious: SDVOSB set-aside: only certified SDVOSBs can bid. You must be registered in SAM.gov and certified as an SDVOSB in the SBA Small Business Search when you bid and before award. SAM.gov's set-aside field says not stated. Check a SAM.gov registration. From 36C24227B0009 Fire Alarm Replacement.pdf
- Serious: Bid bond required with the bid. Copies of the original bid bond must be sent with your emailed bid. A small business needs a surety (bond company) lined up before bidding. Bond amounts are not stated in the text read. From 36C24227B0009 Fire Alarm Replacement.pdf
- Serious: Signed certificates must come with the bid. The limitations on subcontracting certificate and the Buy American certificate must be signed and received with the bid. The subcontracting certificate says offers without it are not considered. From 36C24227B0009 Fire Alarm Replacement.pdf
Show all 10Show fewer
- Serious: Limit on paying non-SDVOSB subcontractors. No more than 75% of the amount the VA pays you may go to firms that are not certified SDVOSBs or VOSBs, so most of the work needs to stay with you or other certified firms. From 852.219-75 VA NOTICE OF LIMITATIONS ON SUBCONTRACTING-CERTIFICATE OF COMPLIANCE FOR SERVICES AND CONSTRUCTION.pdf
- Worth checking: Pre-bid site visit on Tuesday, November 24 at 10:00 AM EST. The visit is at Building 16, Engineering Conference Room, 2094 Albany Post Road, Montrose, NY. Attendance is strongly encouraged, not required, and no other site visits are allowed. From 36C24227B0009 Fire Alarm Replacement.pdf
- Worth checking: Wage determination for Westchester County attached. Construction wage rate requirements apply, and a wage determination (a Department of Labor list of minimum wages) for Westchester County is attached. Use it when pricing labor. From 36C24227B0009 Fire Alarm Replacement.pdf
- Worth checking: Dedicated superintendent and project manager. The superintendent must work only on this project, sign in daily, and no work can happen without them on site. A project manager is also required. These duties start after award. From Specifications-Final.pdf
- Worth checking: Large 28-building job priced building by building. The bid must be itemized by building with a component-level equipment breakdown, plus three alternates and a 5-year maintenance agreement. The Government's range is $2,000,000 to $5,000,000. From Specifications-Final.pdf
- Minor: Questions due December 8, 2026. Questions must be in writing to Daniel.barone@va.gov by 12:00 PM EDT. From 36C24227B0009 Fire Alarm Replacement.pdf
- Minor: Badging and safety training before work starts. Employee names go to the VA COR within ten days of notice to proceed, staff need VA photo badges and fingerprinting, and all employees need a 10-hour OSHA construction safety course. From Specifications-Final.pdf
Read from the notice and 5 attachments. 3 of 8 not read. Show which files.
- Specifications-Final.pdf (read)
- 36C24227B0009 Fire Alarm Replacement.pdf (read)
- Buy American Certificate.pdf (read)
- 852.219-75 VA NOTICE OF LIMITATIONS ON SUBCONTRACTING-CERTIFICATE OF COMPLIANCE FOR SERVICES AND CONSTRUCTION.pdf (read)
- WD - Westchester County.pdf (read)
- 620-22-110 Flash Badge Process Notification.doc: not read (the AI doesn't read this file type yet): open it on SAM.gov
- Fire Alarm Replacement Attachment A - Identification Card Process.doc: not read (the AI doesn't read this file type yet): open it on SAM.gov
- Drawings.pdf: not read (it couldn't be opened): open it on SAM.gov
Full summary
What they want
- Replace and upgrade the fire alarm system campus-wide: 28 existing buildings plus two new buildings (CLC and 7B), each with its own fire alarm control panel (FACP).
- Install a fully addressable, non-proprietary system (NOTIFIER by Honeywell, compatible with the existing NOTIFIER system) that connects to the existing fiber optic loop.
- Set up a master control station in the Fire Department (Building 19) and a second one at the Boiler Plant (Building 20), with voice communication and fire alarm graphics.
- Remove existing fire alarm equipment, conduit and wiring that is not reused, and replace the fire alarm circuit breakers with red, lockable ones.
- Provide a 5-year testing, maintenance and repair agreement (parts and labor) for the new system.
- Give two full days of on-site training by factory-trained representatives for up to ten Fire Department and electrical staff.
- Price the work by building, with a base bid and three alternates (deductions): Alternate 1 removes the new CLC building, Alternate 2 removes CLC and Building 7B, Alternate 3 moves the Building 24 panel to the existing panel room.
- Contract type
- Sealed bid (invitation for bids, or IFB); fixed-price construction (the payment clause for fixed-price construction contracts is included)
- Period of performance
- 550 calendar days from notice to proceed
- Place of performance
- VA Hudson Valley Health Care System, Montrose Campus, 2094 Albany Post Road, Montrose, NY 10548
- Estimated value
- Magnitude of construction: between $2,000,000.00 and $5,000,000.00 (the Government's range)
- Offers due
- December 22, 2026, 10:00 AM ET in the solicitation form; SAM.gov lists December 16, 2026, 10:00 AM Eastern
- How to submit
- Email only to Daniel.barone@va.gov. The bid opening is held online on Microsoft Teams on the due day.
What to include when you submit
- Email your bid; no other way of sending is accepted.
- Include copies of the original bid bond (the guarantee that you will sign the contract if you win).
- Complete and sign the Statement of Bid in specification section 01 00 00, paragraph 1.4, as part of the bid: base bid, Alternates 1 to 3 and the number of completion days.
- Break the bid down by building number, and issue the bid documents separately for each building.
- Give a detailed, component-level breakdown of all fire alarm equipment and devices for each building.
- Send the signed VAAR 852.219-75 Limitations on Subcontracting certificate with the bid.
- Send the signed FAR 52.225-2 Buy American Act certificate with the bid.
- Send your annual Vets4212 Report (the annual federal contractor report on veterans).
- Be registered in SAM.gov with a Unique Entity Identifier (UEI) and certified as an SDVOSB in the SBA Small Business Search when you bid and before award.
- Acknowledge all solicitation amendments.
After award, you must have
- Superintendent with five years of fire alarm installation experience, a direct employee of the general contractor, with a 30-hour OSHA construction safety course. The resume goes to the VA within 30 days of notice to proceed. From Specifications-Final.pdf:
The Superintendent must have five (5) years commercial experience in the installation of Fire Alarm systems.
Current contractor
No incumbent is named in the documents.
Not in the notice text
- Most of the solicitation is missing from what was read: the drawings and the two badge-process Word files were not read, and the middle of the specifications and of the solicitation PDF was left out, including the online bid opening details and the bond and insurance sections.
- The amounts of the bid bond and of any performance and payment bonds are not stated in the text read.
- How the low bidder is chosen is not stated in the text read.
- The Microsoft Teams link and details for the bid opening are said to be on page 17, which was not read.
- The specifications say site visits are by appointment with the Medical Center Engineering Officer, while the solicitation sets a pre-bid site visit on Tuesday, November 24.
- The wage rates in the Westchester County wage determination were not readable here; check it on SAM.gov before pricing.
More to check before you bid
- The notice names requirements:
- The AI summary says this is set aside for service-disabled veteran-owned small businesses (SDVOSBs), but SAM.gov lists no set-aside. Check the notice before you bid.
- SAM.gov's text for this notice doesn't describe the work. The work is described in its attachments, listed under Notice details.
Notice details
Notice type, codes, versions and files
- Posted
- Nov 17, 2026
- Notice type
- Solicitation
- Office
- 242-Network Contract Office 02 (36C242), Albany, NY
- Product/service code
- Y1DA · Construction of Hospitals and Infirmaries
- Business type
- Security & guard services (FedReady's grouping, from NAICS 561621)
- Versions
4 versions have been posted, newest first.
- Nov 17, 2026 · Amendment 0002 (this version)Due Dec 16, 2026
- Nov 17, 2026 · Amendment 0001Due Dec 16, 2026
- Nov 17, 2026 · SolicitationDue Dec 16, 2026
- Oct 28, 2026 · PresolicitationDate Dec 16, 2026
- Attachments
Before you respond
- How to respond to a solicitation (8 steps)
- How to read a government solicitation
- How to price a government contract
Terms on this notice: Solicitation
Full notice text from SAM.gov
Similar open opportunities
- Fort Peck JDC Fire Alarm System UpgradeBureau of Indian Affairs (BIA) solicitation 140A1627Q0108 for a fire alarm and fire suppression system upgrade at the Fort Peck Juvenile Detention Center in Poplar, Montana.
- Fire Alarm BPA Fort Drum NYThe Army contracting office at Fort Drum, NY wants several small businesses to hold Blanket Purchase Agreements (standing agreements for repeat orders) for fire alarm and related…
- Northern California Area Office (NCAO) Fire AlarmOnly Service-Disabled Veteran-Owned Small Business (SDVOSB) firms can bid.
- McCoy Federal Building Fire Alarm Replacement - Jackson, MSSources sought: the General Services Administration, Public Buildings Service, wants a Mississippi licensed fire alarm contractor to replace the fire alarm system at the McCoy…
- Labor-Only Fire Alarm System Support ServicesThe Navy (Naval Air Warfare Center) is running a sources sought, a market research request and not an offer, for labor-only fire alarm system support at NAWS China Lake.