Combined Synopsis/Solicitation
Northern California Area Office (NCAO) Fire Alarm
Department of the Interior
SDVOSB set-aside · CA
A newer version of this notice was posted Nov 23, 2026. It moves the due date from Nov 25, 2026 to Dec 3, 2026, which is the date shown on this page. See the latest version.
AI summary Beta
Summary of the version posted Nov 17, 2026. The notice was amended Nov 23, 2026. The due date moved from Nov 25, 2026 to Dec 3, 2026. Check what else changed on SAM.gov. This summary may miss requirements: 1 of 9 attachments weren't read (C5_5__Attch_5_Wage_Determination.pdf). Check the attachments on SAM.gov.
Only service-disabled veteran-owned small businesses (SDVOSB) can quote on solicitation 140RR027Q0013, fire alarm maintenance for the Bureau of Reclamation's Northern California Area Office (NCAO). The Department of the Interior's Reclamation Contracting Activity wants inspection, testing and repair of Siemens fire alarm systems at ten sites around Shasta Lake, Redding and Lewiston, California. It is a firm-fixed-price (FFP: one set price, whatever the work ends up costing) order from February 1, 2027 through January 31, 2032: a base year plus four option years. The response due date is November 25, 2026, 10:00 AM Pacific, by email.
Who can bid (6)
- Service-disabled veteran-owned small business (SDVOSB): total set-aside, so only these businesses can bid
- Small business under the $25.0 million size standard for NAICS 561621
- Current California Contractor Specialty License, C-10 Electrical Contractor, for the length of the contract; Amendment 0001 says the prime and its subcontractor must both hold C-10 licenses From Sol_140RR027Q0013_Amd_0001.pdf
Show all 6Show fewer
- Amendment 0002: a prime that does none of the regulated electrical or fire alarm work does not need the technician certification, but must hold any California contractor license needed to contract for and manage the work; a licensed C-10 subcontractor must do all regulated work From Sol_140RR027Q0013_Amd_0002.pdf
- Technicians who inspect and test need current National Institute for Certification in Engineering Technologies (NICET) Level III or higher; lower-level staff must be supervised on site by a Level III holder From 140RR027Q0013_Combined_Pre-Sol_Notice_Sol.pdf
- Successful experience with fire alarm systems on the scale of NCAO or larger From 140RR027Q0013_Combined_Pre-Sol_Notice_Sol.pdf
How to submit: Email a signed and dated quote, scanned as PDF, to mouang_phan@ios.doi.gov, due November 25, 2026, 10:00 AM Pacific. What to include is under Full summary below. Check the solicitation's instructions on SAM.gov.
Things to watch (10)
- Serious: Only SDVOSB firms can bid. The order is a total set-aside for service-disabled veteran-owned small businesses; other businesses are not eligible to quote.
- Serious: California C-10 electrical contractor license required. The firm must hold a California C-10 license and give its number with the quote. Amendment 0001 says prime and subcontractor must both hold C-10 licenses; Amendment 0002 says a prime that does no regulated work still needs any California license required to contract for and manage the work. From 140RR027Q0013_Combined_Pre-Sol_Notice_Sol.pdf
- Serious: Only Siemens-certified technicians may work on the system. The Siemens equipment is proprietary, so a business without Siemens-certified technicians, its own or a subcontractor's, cannot do the repairs. From 140RR027Q0013_Combined_Pre-Sol_Notice_Sol.pdf
Show all 10Show fewer
- Serious: Required documents must come with the quote. Quotes without the technical capability documents (licenses, certifications, safety program) are not considered, and Amendments 0001 and 0002 must be signed and returned. From 140RR027Q0013_Combined_Pre-Sol_Notice_Sol.pdf
- Worth checking: Level III fire alarm certification required for technicians. Staff doing inspection, testing and repairs need National Institute for Certification in Engineering Technologies (NICET) Level III or higher; Amendment 0001 says NICET Level III and Siemens factory certification are separate requirements and both must be met. From Sol_140RR027Q0013_Amd_0001.pdf
- Worth checking: Response time for non-routine repairs. After a failure beyond routine maintenance, the contractor must respond within 3 business days and give a repair plan with cost within 10 business days. From 140RR027Q0013_Combined_Pre-Sol_Notice_Sol.pdf
- Minor: The site visit was Nov 9, 2026. Check the notice and its amendments for whether attendance was required, and whether another visit is offered. From 140RR027Q0013_Combined_Pre-Sol_Notice_Sol.pdf
- Minor: Escort at all times and weekday hours. Work is on site only Monday through Friday, 7:00 AM to 5:00 PM, and the contracting officer's representative (COR: the Government's day-to-day contract contact) escorts contractor staff whenever they are on site. From 140RR027Q0013_Combined_Pre-Sol_Notice_Sol.pdf
- Minor: Government spare parts must be replaced within 30 calendar days. Any Government-owned spare part used must be ordered, delivered and stocked again within 30 calendar days of use, at no extra cost. From 140RR027Q0013_Combined_Pre-Sol_Notice_Sol.pdf
- Minor: Replaces an earlier solicitation number. This solicitation replaces 140R2026Q00116; a business that looked at the old number should use the new documents and amendments.
Read from the notice and 8 attachments. 1 of 9 not read. Show which files.
- Sol_140RR027Q0013_Amd_0002.pdf (read)
- Sol_140RR027Q0013_Amd_0001.pdf (read)
- Sol_140RR027Q0013.pdf (read)
- 140RR027Q0013_Combined_Pre-Sol_Notice_Sol.pdf (read)
- C5_5__Attch_2_Major_Fire_Alarm_System_Components.PDF (read)
- C5_5__Attch_3__Inspection-Testing_List.pdf (read)
- C5_5__Attch_4_RSHS_Appendix_1_03-C_Safety_Program.pdf (read)
- C5_5__Attch_1_Fire_Alarm_Reporting_Diagram.PDF (read)
- C5_5__Attch_5_Wage_Determination.pdf: not summarized: open it on SAM.gov
Full summary
What they want
- Inspect and test the fire alarm systems at ten facilities to National Fire Protection Association (NFPA) 72, the national fire alarm code. Each year's estimate is: contract line item number (CLIN) 0010 monthly at 6 facilities, EA 72; CLIN 0020 semi-annual at 10 facilities, EA 20; CLIN 0030 annual at 10 facilities, EA 10
- Routine corrective maintenance during those visits, with replacement parts on hand (detectors, strobes, pull stations, power supplies, batteries)
- Non-routine repairs, estimated at HR 120 a year (CLIN 0040): respond within 3 business days of notice, and give a repair plan with cost estimate within 10 business days; the Government approves before work starts
- Send a baseline inspection and testing schedule within 14 calendar days of award, and a new one at least 21 calendar days before each option year
- Document all inspection and testing under NFPA 72 and give the reports to the Government within 10 calendar days
- Replace any Government spare part you use within 30 calendar days, and do software and firmware updates to Siemens and Bosch equipment as those makers recommend
- Write a safety program in the Bureau of Reclamation outline for approval by the Contracting Officer's Representative (COR: the Government's day-to-day contract contact) before mobilizing
- Work on site Monday through Friday, 7:00 AM to 5:00 PM except Federal holidays, with a Government escort at all times
- Contract type
- Firm-fixed-price purchase order
- Period of performance
- 1 base year + 4 option years, approximately February 1, 2027 through January 31, 2032; price evaluation also counts a 6-month extension under FAR 52.217-8
- Place of performance
- Ten Northern California Area Office facilities in Shasta Lake, Redding and Lewiston, California (Shasta Powerplant, Shasta Dam, Upper Vista House, Shasta Maintenance Center, Keswick Office Building, Keswick Powerplant, Spring Creek Powerplant, J.F. Carr Powerplant, Lewiston Powerplant, Trinity Powerplant)
- Remote work
- No. From 140RR027Q0013_Combined_Pre-Sol_Notice_Sol.pdf:
The Contractor will conduct on-site business for fire alarm system inspection, testing, troubleshooting, and repairs between the hours of 7:00 A.M. to 5:00 P.M. Monday through Friday, except Federal holidays or when the Government facility is closed due to local or national emergencies, administrative closings, or similar Government directed facility closings.
- Estimated value
- Not stated
- How they'll choose
- Comparative evaluation for best value (the Government compares quotes with each other on technical capability, prior experience, past performance and price)
- Offers due
- November 25, 2026, 10:00 AM Pacific (from the version posted Nov 17, 2026; amended since)
- How to submit
- Email a signed and dated quote, scanned as PDF, to mouang_phan@ios.doi.gov
What they'll judge offers on
- Technical Capability: (a) current company and proposed personnel licenses and certifications, including a qualified Siemens-certified technician, (b) your safety program
- Prior Experience: successful fire alarm work on the scale of NCAO (10 geographically separate facilities, hundreds of maintenance actions a year) or larger
- Past Performance: checked in the Contractor Performance Assessment Reporting System (CPARS: the Government's past-performance database), SAM.gov, customer surveys and other sources; a neutral rating if none is available
- Price: checked for reasonableness and unbalanced pricing; total evaluated price is the base year, all option years and a 6-month extension
What to include when you submit
- Send the completed and signed page 3 of the solicitation (vendor name, UEI or CAGE code, authorized signature, business size) and the completed pricing schedule for the base year and all four option years
- Send technical capability documents showing you can meet the performance requirements: current company and proposed personnel licenses and certifications, and your safety program
- Send prior experience documents for the Prior Experience factor
- Include your California Contractor license number and valid, current certification documents for your technicians; Amendment 0001 says the Siemens factory certification does not need to come with the quote
- Sign and send a copy of Standard Form 30 (SF-30: the amendment form) for each amendment, 0001 and 0002, with the quote
After award, you must have
- Technicians who do routine corrective maintenance or repairs must be Siemens factory-certified; per Amendment 0001 this is shown at the kickoff meeting after award, and again for any technician change From Sol_140RR027Q0013_Amd_0001.pdf:
The certification is only required after contract award, during the kickoff meeting…
Not in the notice text
- Attached but only partly read: the middle of 140RR027Q0013_Combined_Pre-Sol_Notice_Sol.pdf (about 54,000 characters, including the end of the statement of work and the contract clauses) and of C5_5__Attch_2_Major_Fire_Alarm_System_Components.PDF were left out; the table of contents lists liability insurance and security requirements clauses whose terms were not read
- C5_5__Attch_5_Wage_Determination.pdf is attached but not read (scanned PDF with no text); check it on SAM.gov for the wage rates that apply
- The question deadline is not stated
- The Government's estimate is not stated
- Which California license class the prime needs when a C-10 subcontractor does all regulated work should be confirmed with the contracting officer, since Amendments 0001 and 0002 word it differently
More to check before you bid
- Not certified through VetCert yet? Apply on VetCert (SBA), or start with the SDVOSB guide. More open service-disabled veteran-owned set-asides under NAICS 561621
Notice details
Notice type, codes, versions and files
- Posted
- Nov 17, 2026
- Notice type
- Combined Synopsis/Solicitation
- Office
- Reclamation Contracting Activity, Denver, CO
- Product/service code
- H912 · Other QC/Test/Inspect – Fire Control Equipment
- Business type
- Security & guard services (FedReady's grouping, from NAICS 561621)
- Versions
4 versions have been posted, newest first.
- Nov 23, 2026 · Amendment 0003Due Dec 3, 2026 (changed)
- Nov 17, 2026 · Amendment 0002 (this version)Due Nov 25, 2026 (changed)
- Nov 4, 2026 · Amendment 0001Due Nov 4, 2026 (changed)
- Oct 27, 2026 · Combined Synopsis/SolicitationDue Nov 25, 2026
- Attachments
Before you respond
- How to respond to a solicitation (8 steps)
- How to read a government solicitation
- How to price a government contract
- Open SDVOSB set-aside contracts
Terms on this notice: Solicitation, SDVOSB (service-disabled veteran-owned small business), Set-aside
Full notice text from SAM.gov
Similar open opportunities
- Anti-Ligature Door Alarm Installation ServicesThe Department of Veterans Affairs is asking service-disabled veteran-owned small businesses (SDVOSBs) to quote on anti-ligature door alarm installation services at the San Diego…
- Fort Peck JDC Fire Alarm System UpgradeBureau of Indian Affairs (BIA) solicitation 140A1627Q0108 for a fire alarm and fire suppression system upgrade at the Fort Peck Juvenile Detention Center in Poplar, Montana.
- Project620-22-110 Replace and Upgrade Fire alarm System at Montrose VAMCSolicitation 36C24227B0009_1: only certified service-disabled veteran-owned small businesses (SDVOSBs) can bid on this sealed-bid construction job (an invitation for bids, where…
- Fire Alarm BPA Fort Drum NYThe Army contracting office at Fort Drum, NY wants several small businesses to hold Blanket Purchase Agreements (standing agreements for repeat orders) for fire alarm and related…
- 16806 Redw Fire and Intrusion Alarm Syst