Combined Synopsis/Solicitation
NH100 Engine Control Unit Replacement
Department of Defense · Department of the Navy
Small business set-aside · Camp Lejeune, NC
AI summary Beta
This summary may miss requirements: 1 of 6 attachments weren't read (Amend 0001.pdf). Check the attachments on SAM.gov.
Only the four holders of the Navy's M&R MACC (multiple award construction contract) named on the cover page can bid on this combined synopsis/solicitation from the Naval Facilities Engineering Systems Command (NAVFAC) Mid-Atlantic, ROICC Camp Lejeune. The job is to replace the engine control units (ECUs) on three emergency generators at the Naval Medical Center Camp Lejeune hospital, Building NH100, with the lowest price winning. The General Requirements give an estimated cost range of $500,000 to $1,000,000; the response due date is December 4, 2026, 1:00 PM Eastern.
Who can bid (4)
- Limited competition: only the four holders of the Navy's M&R MACC can bid, not every business that meets the set-aside.
- Total small business set-aside From SAM.gov's set-aside field
- Must be one of the four M&R MACC holders listed on the General Requirements cover page From RFP 270700.pdf
Show all 4Show fewer
- Bid bond of 20% of the proposal amount for proposals of $150K and greater; payment and performance bonds are requested at award From RFP 270700.pdf
How to submit: Email to jessica.r.huebner.civ@us.navy.mil and lauren.f.loconto.civ@us.navy.mil. What to include is under Full summary below. Check the solicitation's instructions on SAM.gov.
Things to watch (10)
From the version posted Nov 20, 2026.
- Serious: Only four named MACC holders may bid. A business that does not hold one of the four listed M&R MACC contracts cannot send a proposal.
- Serious: Bid bond required for proposals of $150K and greater. The estimated cost range starts at $500,000, so a bid bond of 20% of the proposal amount is likely needed; leaving it out removes the proposal from consideration. From RFP 270700.pdf
- Serious: OEM-certified technicians and OEM-authorized sourcing required. Only factory-certified Detroit Diesel/MTU technicians may do the engine work, so a bidder must team with an authorized MTU distributor and price a custom upfit kit. From NH100 REPLACE ENGINE CONTROL UNITS ON 3 GENERATORS revised.pdf
Show all 10Show fewer
- Worth checking: Switchgear manufacturer subcontract and independent Commissioning Agent required. The bidder must hire a Commissioning Agent and subcontract RussElectric/Siemens field service, and must price both. From NH100 REPLACE ENGINE CONTROL UNITS ON 3 GENERATORS revised.pdf
- Worth checking: Liquidated damages of $4,686.73 per calendar day. Late completion of the 60-day on-site window costs this amount for every calendar day. From RFP 270700.pdf
- Worth checking: Long-lead OEM materials must all be on site before installation starts. All OEM parts must be on site and inventoried with the COR before installation starts, and lead times are not published until an order is placed. From NH100 REPLACE ENGINE CONTROL UNITS ON 3 GENERATORS revised.pdf
- Worth checking: Work in an operating hospital, generators taken out in a set order. The hospital stays in operation, and generator 2 cannot be taken out of service until generators 1 and 3 are upgraded, tested and certified. From NH100 REPLACE ENGINE CONTROL UNITS ON 3 GENERATORS revised.pdf
- Minor: Working hours differ between documents. The project description allows 0700 to 1900, Monday through Friday, while the Division 01 specification lists regular hours of 0730 to 1600; ask the contracting officer which applies. From NH100 REPLACE ENGINE CONTROL UNITS ON 3 GENERATORS revised.pdf
- Minor: The site visit was Nov 16, 2026. Check the notice and its amendments for whether attendance was required, and whether another visit is offered. From RFP 270700.pdf
- Minor: Funding may not become available. If funds are not available, no award is made and bidders are not repaid for proposal costs. From RFP 270700.pdf
Read from the notice and 5 attachments. 1 of 6 not read. Show which files.
- RFP 270700.pdf (read)
- Amend 0003.pdf (read)
- Amend 0002.pdf (read)
- NH100 REPLACE ENGINE CONTROL UNITS ON 3 GENERATORS revised.pdf (read)
- Combined DIV 01 specs small projects.pdf (read)
- Amend 0001.pdf: not summarized: open it on SAM.gov
Full summary
What they want
- Replace the engine control units on all three emergency generators at Building NH100, along with the matching onboard controllers, custom wiring harnesses, pulse-controlled fuel injectors and voltage regulators
- Use factory-certified Detroit Diesel/MTU technicians (a minimum of 2 on site at the same time) for the engine work and the control-unit programming
- Subcontract the paralleling switchgear manufacturer's (RussElectric/Siemens) field engineer to be on site for integration and testing
- Hire an independent Commissioning Agent (a third-party tester) to run the full-capacity load tests and the Emergency Power Supply System acceptance test under NFPA 110, the fire-code standard for emergency power
- Work in two phases: generators 1 and 3 first, then generator 2; generator 2 stays in service until the other two are upgraded and certified
- Phase I of the schedule is submittals (due within 15 calendar days of award) and ordering OEM materials, which does not count against the 60 calendar days of on-site work that follow
- Provide up to 4 hours of documented hands-on training, 3 hardcopies and 1 PDF of the operations and maintenance manuals, as-built wiring diagrams and the final commissioning report
- Provide the temporary load banks and cables for testing; the Government supplies the diesel fuel. Wages follow Davis-Bacon wage determination NC20260010
- Contract type
- Construction contract task order under the M&R MACC; the solicitation is a combined synopsis/solicitation
- Period of performance
- 60 days after the Contracting Officer's Representative (COR) has verified on-site receipt of the OEM materials; submittals are due within 15 calendar days of award and ordering time does not count against the 60 days
- Place of performance
- Naval Medical Center Camp Lejeune, Building NH100, Camp Lejeune, North Carolina
- Estimated value
- Estimated cost range of between $500,000 and $1,000,000 (General Requirements)
- Contract vehicle
- M&R MACC; only the contractors listed on the General Requirements cover page (contract numbers N40085-25-D-2516, N40085-25-D-2517, N40085-25-D-2518 and N40085-25-D-2519) may submit a proposal
- How they'll choose
- Lowest price
- Offers due
- December 4, 2026, 1:00 PM Eastern
- How to submit
- Email to jessica.r.huebner.civ@us.navy.mil and lauren.f.loconto.civ@us.navy.mil
What they'll judge offers on
- Price
What to include when you submit
- Send the proposal by email to both addresses above
- Include a bid bond for 20% of the proposal amount when required; an electronic copy may be sent with the proposal, using the bond formats at FAR 53.300
- Proposals of $150K and greater need a bid bond, a payment bond and a performance bond; payment and performance bonds are requested at award
- Send requests for information (RFIs) only to jessica.r.huebner.civ@us.navy.mil, by the RFI cut-off of November 30, 2026, 2:00 PM EST
- The proposal acceptance period is 30 days from receipt of offers
- If offering foreign construction material not listed by the Government, the Buy American provision (FAR 52.225-10) allows an alternate offer with a separate Standard Form 1442 and price comparison table
After award, you must have
- All engine and control-unit work, including programming and firmware flashing, done by factory-certified technicians from an authorized Detroit Diesel/MTU representative; proof of certification goes in the technical submittal package From NH100 REPLACE ENGINE CONTROL UNITS ON 3 GENERATORS revised.pdf:
…shall only be performed by factory-certified technicians from an authorized representative of Detroit Diesel/MTU (e.g., Curtis Power Solutions).
- Independent, verified Commissioning Agent with experience restoring compliance of healthcare emergency power systems From NH100 REPLACE ENGINE CONTROL UNITS ON 3 GENERATORS revised.pdf:
The Contractor shall hire an independent, verified Commissioning Agent that has validated experience restoring compliance to legally required healthcare emergency power distribution systems.
- Subcontract directly with the switchgear manufacturer (RussElectric/Siemens Field Service) for a factory-certified field service engineer From NH100 REPLACE ENGINE CONTROL UNITS ON 3 GENERATORS revised.pdf:
The Contractor shall subcontract directly with the installed paralleling switchgear manufacturer…
Current contractor
No incumbent is named. The document says the existing engine control units have failed and cannot be repaired.
Not in the notice text
- Amendment 0001 is attached but not read (a scanned PDF with no readable text); it may change terms
- The Division 01 specifications file is attached but only partly read (the middle was left out)
- Whether the November 16, 2026 site visit is required is not stated
- Which working hours apply (0700 to 1900 or 0730 to 1600) is unclear
- Whether remote work is allowed is not stated; the work is on site at the hospital
More to check before you bid
- The notice names requirements:
- Limited competition: only the four holders of the Navy's M&R MACC can bid, not every business that meets the set-aside.
- Construction contracts over $2,000 pay at least the local Davis-Bacon wage rates, from the wage determination in the solicitation. Price your labor from it: How to price a government contract, and how Davis-Bacon differs from the Service Contract Act.
Notice details
Notice type, codes, versions and files
- Posted
- Nov 20, 2026
- Notice type
- Combined Synopsis/Solicitation
- Office
- Navfacsyscom Mid-Atlantic, Norfolk, VA
- Product/service code
- Z2DA · Repair or Alteration of Hospitals and Infirmaries
- Business type
- Construction & renovation (FedReady's grouping, from NAICS 236220)
- Versions
4 versions have been posted, newest first.
- Nov 20, 2026 · Amendment 0003 (this version)Due Dec 4, 2026
- Nov 19, 2026 · Amendment 0002Due Dec 4, 2026
- Nov 16, 2026 · Amendment 0001Due Dec 4, 2026
- Nov 13, 2026 · Combined Synopsis/SolicitationDue Dec 4, 2026
- Attachments
Before you respond
- How to respond to a solicitation (8 steps)
- How to read a government solicitation
- How to price a government contract
- Set-aside contracts explained
Terms on this notice: Solicitation, Set-aside
Full notice text from SAM.gov
Similar open opportunities
- CRAC Units Replacement for MCE 1211 at GFAFB, NDOnly small businesses can bid on combined synopsis/solicitation FA465927QM001, set aside 100% for small business.