Combined Synopsis/Solicitation
NH100 Engine Control Unit Replacement
Department of Defense · Department of the Navy
Small business set-aside · Camp Lejeune, NC
A newer version of this notice was posted Nov 20, 2026. See the latest version.
AI summary Beta
Summary of the version posted Nov 16, 2026. The notice was amended Nov 20, 2026. Check what else changed on SAM.gov. This summary may miss requirements: 1 of 4 attachments weren't read (Amend 0001.pdf). Check the attachments on SAM.gov.
Only the four M&R multiple-award construction contract (MACC) holders listed in the solicitation can bid on N40085-27-R-9006, NH100 Engine Control Unit Replacement. NAVFAC Mid-Atlantic, for ROICC Camp Lejeune, wants engine control units (ECUs, the computers that run each engine) replaced on 3 emergency generators at the Naval Hospital, Building NH100, Camp Lejeune, NC. The work needs factory-certified technicians, a commissioning agent and NFPA 110 acceptance testing; the response due date is December 4, 2026, 1:00 PM Eastern.
Who can bid (4)
- Limited competition: only four named MACC holders can bid, not every business that meets the set-aside.
- Be one of the four listed M&R MACC contract holders (N40085-25-D-2516, -2517, -2518 or -2519)
- Small business (SAM.gov set-aside: Small Business Set Aside - Total)
Show all 4Show fewer
- Bid bond of 20% of the proposal amount with the proposal, because the estimated cost range is above $150,000 From RFP 270700.pdf
How to submit: Email to jessica.r.huebner.civ@us.navy.mil and lauren.f.loconto.civ@us.navy.mil. What to include is under Full summary below. Check the solicitation's instructions on SAM.gov.
Things to watch (11)
- Serious: Only four named MACC holders can bid. Unless your company holds one of the four listed M&R MACC contracts, you cannot send a proposal for this project.
- Serious: Bid bond required with the proposal. At this estimated cost, the proposal needs a bid bond of 20% of the amount, plus payment and performance bonds at award; a missing bid bond removes the proposal. From RFP 270700.pdf
- Serious: Factory-certified OEM technicians required. Only Detroit Diesel/MTU factory-certified technicians may do the engine-side work and ECU programming, with at least 2 on site at once, so a bidder needs an authorized OEM partner. From NH100 REPLACE ENGINE CONTROL UNITS ON 3 GENERATORS revised.pdf
Show all 11Show fewer
- Worth checking: Required subcontract with the switchgear maker and a commissioning agent. You must hire the switchgear manufacturer's field service and an independent commissioning agent, and arrange full-capacity load banks and feeder cables at your own cost. From NH100 REPLACE ENGINE CONTROL UNITS ON 3 GENERATORS revised.pdf
- Worth checking: Liquidated damages of $4,686.73 per calendar day. Liquidated damages are a daily charge for finishing late, so the 60-day on-site window carries real cost if the work slips. From RFP 270700.pdf
- Worth checking: Parts lead times set the schedule. Ordering starts after submittal approval and does not count against the 60 days, but all OEM materials must be on site and inventoried before installation begins; lead times are not published. From NH100 REPLACE ENGINE CONTROL UNITS ON 3 GENERATORS revised.pdf
- Worth checking: The site visit was Nov 16, 2026. Check the notice and its amendments for whether attendance was required, and whether another visit is offered. From RFP 270700.pdf
- Worth checking: Amendment 0001 attached but not read. Amendment 0001 is a scanned file whose text could not be read here; it may change dates or requirements, so check it on SAM.gov.
- Worth checking: Work in two parts: Generators 1 and 3, then Generator 2. The Government inspects the first part before the second starts, and Generator 2 must stay in service until the other two pass testing, which limits how you can schedule crews. From NH100 REPLACE ENGINE CONTROL UNITS ON 3 GENERATORS revised.pdf
- Minor: Work hours limited and hospital stays open. Work is limited to set hours and must be coordinated with hospital facility staff because the building stays in operation. From NH100 REPLACE ENGINE CONTROL UNITS ON 3 GENERATORS revised.pdf
- Minor: Funding may not become available. The Government may make no award if funds are not available, and bidders are not repaid for proposal costs. From RFP 270700.pdf
Read from the notice and 3 attachments. 1 of 4 not read. Show which files.
- RFP 270700.pdf (read)
- NH100 REPLACE ENGINE CONTROL UNITS ON 3 GENERATORS revised.pdf (read)
- Combined DIV 01 specs small projects.pdf (read)
- Amend 0001.pdf: not summarized: open it on SAM.gov
Full summary
What they want
- Replace the engine control units on 3 emergency generators at Building NH100, with the matching OEM controllers, wiring harnesses, fuel injectors and voltage regulators
- Use factory-certified Detroit Diesel/MTU technicians (at least 2 on site at once) for the engine-side work and ECU programming
- Subcontract the switchgear maker (RussElectric/Siemens Field Service) to put a field engineer on site for integration and testing
- Hire an independent commissioning agent and run the NFPA 110 acceptance test with full-capacity load banks, witnessed by the Government
- Work in order: Generators 1 and 3 first, then Generator 2; Generator 2 stays in service until the other two are tested and certified
- Order the OEM parts after submittals are approved, and have 100% of them on site and inventoried before installation starts
- Finish on-site installation, testing and closeout within 60 calendar days of verified receipt of all OEM materials
- Give up to 4 hours of hands-on training, 3 hard copies and 1 PDF of the manuals, as-built wiring diagrams and final commissioning reports
- Period of performance
- Submittals due 15 calendar days after award, then OEM ordering (not counted against the construction window), then 60 calendar days of on-site work after the COR verifies receipt of all OEM materials
- Place of performance
- Building NH100, Naval Medical Center Camp Lejeune, Camp Lejeune, NC
- Estimated value
- Estimated cost range: between $500,000 and $1,000,000
- Contract vehicle
- Only holders of M&R MACC contracts N40085-25-D-2516 (T.E. Davis Construction Company), N40085-25-D-2517 (Joyce & Associates Construction, Inc.), N40085-25-D-2518 (Olympic Enterprises, Inc.) and N40085-25-D-2519 (Quadrant Construction)
- How they'll choose
- Lowest price
- Offers due
- December 4, 2026, 1:00 PM Eastern (from the version posted Nov 16, 2026; amended since)
- How to submit
- Email to jessica.r.huebner.civ@us.navy.mil and lauren.f.loconto.civ@us.navy.mil
What they'll judge offers on
- Price
What to include when you submit
- Send the proposal by email to both addresses above.
- Include a bid bond (a guarantee that you will sign the contract if you win) for 20% of the proposal amount; an electronic copy may be sent with the proposal. Use the bond formats at FAR 53.300.
- Proposals must stay open for 30 days from receipt of offers.
- Send requests for information (RFIs) only to jessica.r.huebner.civ@us.navy.mil.
- The specifications and drawings are posted as attachments on SAM.gov.
After award, you must have
- Payment and performance bonds, requested at award From RFP 270700.pdf:
Payment and/or performance bond(s) will be requested at the time of award per the current…
- Factory-certified Detroit Diesel/MTU technicians (authorized representative), with proof of certification in the technical submittal package From NH100 REPLACE ENGINE CONTROL UNITS ON 3 GENERATORS revised.pdf:
…shall only be performed by factory-certified technicians from…
- A direct subcontract with the switchgear manufacturer's field service (RussElectric/Siemens Field Service) From NH100 REPLACE ENGINE CONTROL UNITS ON 3 GENERATORS revised.pdf:
The Contractor shall subcontract directly with the installed paralleling switchgear manufacturer…
- An independent, verified commissioning agent with experience restoring compliance of healthcare emergency power systems From NH100 REPLACE ENGINE CONTROL UNITS ON 3 GENERATORS revised.pdf:
The Contractor shall hire an independent, verified Commissioning Agent that has…
Not in the notice text
- Amendment 0001 is attached on SAM.gov but not read here (a scanned file), and only part of the Division 01 general specifications was read; check both on SAM.gov for changes.
- The text does not say whether the November 16, 2026 site visit is mandatory.
- The wage determination listed is General Decision NC20260010 (Building) dated May 18, 2026; the text does not say which job classifications apply to the generator work.
- OEM lead times for the engine control units, harnesses, injectors and voltage regulators are not given.
- The contract type (such as firm-fixed-price) is not stated in the documents read.
More to check before you bid
- The notice names requirements:
- Limited competition: only four named MACC holders can bid, not every business that meets the set-aside.
Notice details
Notice type, codes, versions and files
- Posted
- Nov 16, 2026
- Notice type
- Combined Synopsis/Solicitation
- Office
- Navfacsyscom Mid-Atlantic, Norfolk, VA
- Product/service code
- Z2DA · Repair or Alteration of Hospitals and Infirmaries
- Business type
- Construction & renovation (FedReady's grouping, from NAICS 236220)
- Versions
4 versions have been posted, newest first.
- Nov 20, 2026 · Amendment 0003Due Dec 4, 2026
- Nov 19, 2026 · Amendment 0002Due Dec 4, 2026
- Nov 16, 2026 · Amendment 0001 (this version)Due Dec 4, 2026
- Nov 13, 2026 · Combined Synopsis/SolicitationDue Dec 4, 2026
- Attachments
Before you respond
- How to respond to a solicitation (8 steps)
- How to read a government solicitation
- How to price a government contract
- Set-aside contracts explained
Terms on this notice: Solicitation, Set-aside
Full notice text from SAM.gov
Similar open opportunities
- CRAC Units Replacement for MCE 1211 at GFAFB, NDOnly small businesses can bid on combined synopsis/solicitation FA465927QM001, set aside 100% for small business.