Solicitation
Upgrade Fire Alarm System Construction 676-22-110
Department of Veterans Affairs
SDVOSB set-aside · Tomah, WI
A newer version of this notice was posted Nov 19, 2026. It moves the due date from Sep 22, 2026 to Dec 1, 2026, which is the date shown on this page. See the latest version.
AI summary Beta
Summary of another version of this notice: check what changed on SAM.gov. This summary may miss requirements: 17 of 29 attachments weren't read (S02 - PART 3 - FIRE ALARM DEMO PLANS 20260421.pdf, S02 - PART 6 - FIRE ALARM NEW PLANS 20260421.pdf and 15 more). Check the attachments on SAM.gov.
Solicitation 36C25226B0014-1: the Department of Veterans Affairs (VA) wants a new campus-wide fire alarm system at the Tomah VA Medical Center in Tomah, Wisconsin, and only service-disabled veteran-owned small businesses (SDVOSB) can bid. Sealed bids go by email, and the response due date is December 1, 2026, 10:00 AM Central, followed by a public virtual bid opening. The work replaces all existing alarm devices and wiring in an occupied hospital campus, under infection control rules.
Who can bid
- Service-disabled veteran-owned small business (SDVOSB) set-aside: SAM.gov lists this as an SDVOSB set-aside under FAR 19.14, so only SDVOSBs can bid From SAM.gov's set-aside field
- Site safety and health officer (SSHO) separate from the superintendent and the quality control manager, with 30-hour OSHA (Occupational Safety and Health Administration) construction safety training in the last five years plus 7 years of construction safety experience (or other combinations listed) From S06 - RFI Response A0001 Sep 3 2026.pdf
- Construction quality control (CQC) system manager employed by the general contractor, on site at all times during construction, with a construction management degree and 5 years of similar experience, plus a named alternate with the same qualifications From S06 - RFI Response A0001 Sep 3 2026.pdf
How to submit: Email to both Contracting Officer addresses, Lynn.VanderVelde@va.gov and Ryan.McMillin@va.gov, with the subject 36C25226B0014. What to include is under Full summary below. Check the solicitation's instructions on SAM.gov.
Things to watch (11)
From the version posted Nov 19, 2026.
- Serious: Set aside for service-disabled veteran-owned small businesses. SAM.gov lists an SDVOSB set-aside, so only SDVOSBs can bid; a business without that status cannot compete.
- Worth checking: Named safety and quality control people required. The Government confirmed the safety officer and quality control manager must be separate people who meet the specification's qualifications; a small firm may need to hire or team for them. From S06 - RFI Response A0001 Sep 3 2026.pdf
- Worth checking: Work in an occupied hospital under infection control rules. Work areas carry infection control classes, barriers or HEPA carts, and monitoring, which add cost and slow the work. From S06 - RFI Response A0001 Sep 3 2026.pdf
Show all 11Show fewer
- Worth checking: Existing alarm must stay live during the work. The old system must keep working until the new one is in place, so cutover has to be planned building by building. From S02 - Bid Specifications_20260421.pdf
- Minor: Response due date has been moved several times. Amendments moved the date from September 22 to October 20, then November 4, then December 1, 2026; Amendment 0004 sets 10:00 AM Central on December 1, 2026. From 36C25226B0014 0004.docx
- Minor: Price the base bid only. The specifications list Alternates 1 to 6, but the Government's RFI response says to price the base bid only. From S06 - RFI Response A0001 Sep 3 2026.pdf
- Minor: System type: IDP or equivalent. The Government asks for an IDP or equivalent fully addressable loop system; check that your chosen manufacturer meets it. From 36C25226B0014 0006.docx
- Minor: Building automation link must be disconnected by the VA's contractor. The fire alarm contractor must hire Johnson Controls, named in Amendment A0005, to disconnect the building automation link, and carry that cost. From 36C25226B0014 0005.docx
- Minor: Pre-construction submissions due within 60 days after notice to proceed. Amendment 0003 extended the period for pre-construction submissions from 20 days to 60 days. From 36C25226B0014 0003.docx
- Minor: Site visit dates are given two ways. The sign-in sheet header says September 25 and 27, 2026, but its entries and file name show August 25 and 27; site visits are by appointment with the COR. From S06 - Site Visit Sign-in Aug 25 27-2026.pdf
- Minor: One year of maintenance after acceptance. The contractor must keep the system running for a year after formal written acceptance, including inspections and 24-hour emergency service. From S02 - Bid Specifications_20260421.pdf
Read from the notice and 12 attachments. 17 of 29 not read. Show which files.
- S06 - RFI Response A0001 Sep 3 2026.pdf (read)
- S02 - Bid Specifications_20260421.pdf (read)
- 36C25226B0014 0006.docx (read)
- 36C25226B0014 0005.docx (read)
- 36C25226B0014 0004.docx (read)
- 36C25226B0014 0003.docx (read)
- S06 - 36C25226B0014 0002.pdf (read)
- S06 - Low Risk Locations - Upgrade Fire Alarm.pdf (read)
- S06 - High-Highest Risk Locations - Upgrade Fire Alarm.pdf (read)
- S06 - Medium Risk Locations - Upgrade Fire Alarm 02.pdf (read)
- S06 - Site Visit Sign-in Aug 25 27-2026.pdf (read)
- 36C25226B0014 0001.docx (read)
- S02 - PART 3 - FIRE ALARM DEMO PLANS 20260421.pdf: not summarized: open it on SAM.gov
- S02 - PART 6 - FIRE ALARM NEW PLANS 20260421.pdf: not summarized: open it on SAM.gov
- S02 - PART 7 - FIRE ALARM NEW PLANS 20260421.pdf: not summarized: open it on SAM.gov
- S02 - PART 4 - FIRE ALARM DEMO PLANS 20260421.pdf: not summarized: open it on SAM.gov
- S02 - 36C25226B0014.docx: not summarized: open it on SAM.gov
- S06 - Att 1 RFI Response A0005 FINAL 20261104.pdf: not summarized: open it on SAM.gov
- S06 - Att 3 RFI Response A0003 Oct 6 2026.pdf: not summarized: open it on SAM.gov
- S06 - Att 2 Addendum No2_20261104.pdf: not summarized: open it on SAM.gov
- S06 - Att 2 Addendum No1 676-22-110 Upgrade Fire Alarm System 20260929.pdf: not summarized: open it on SAM.gov
- S06 - Att 1 Updates to Pages 3 and 11 of SOL 36C25226B0014.pdf: not summarized: open it on SAM.gov
- S06 - Infection Control 676-22-110 Upgrade Fire Alarm.pdf: not summarized: open it on SAM.gov
- S02 - PART 9 - ELECTRICAL DRAWINGS 20260421.pdf: not summarized: open it on SAM.gov
- S02 - PART 8 - FIRE ALARM NEW ONE-LINE DIAGRAMS 20260421.pdf: not summarized: open it on SAM.gov
- S02 - PART 5 - FIRE ALARM DEMO ONE-LINE DIAGRAMS 20260421.pdf: not summarized: open it on SAM.gov
- S02 - PART 2 - CIVIL DRAWINGS 20260421.pdf: not summarized: open it on SAM.gov
- S02 - PART 1 - GENERAL DRAWINGS 20260421.pdf: not summarized: open it on SAM.gov
- S02 - Wage Determination WI20260011 Building Mod 1 20260518.pdf: not summarized: open it on SAM.gov
Full summary
What they want
- Replace the campus-wide fire alarm system: all existing devices and wiring, including building control panels, radio receivers, smoke detectors, pull stations, strobes, relays, sprinkler alarms and local announcement microphones
- Replace the main alarm control stations in the Firehouse (Building 36) and for Emergency Dispatch (Building 407)
- Extend the fire alarm system to out-buildings not covered by the current system
- Keep the existing system active until the new system is in place
- Provide an intelligent device protocol (IDP) system, or equivalent, that is fully addressable on a loop with real-time data
- Follow infection control risk assessment (ICRA) rules, including barriers or HEPA (high-efficiency air filter) carts, while working in occupied buildings
- Hire the VA's building automation system contractor to disconnect the link between the fire alarm and that system
- Keep the system working for one year after formal written acceptance, including inspections and emergency service
- Contract type
- Sealed bid (bids opened in a public virtual opening); price the base bid only
- Period of performance
- 460 calendar days after notice to proceed in total, including VA review time, per the chart in Amendment 0003 (pre-construction 60 days, campus work 350 days, closeout 10 days, plus review periods)
- Place of performance
- Tomah VA Medical Center, Tomah, Wisconsin
- Estimated value
- Not stated
- Offers due
- December 1, 2026, 10:00 AM Central
- How to submit
- Email to both Contracting Officer addresses, Lynn.VanderVelde@va.gov and Ryan.McMillin@va.gov, with the subject 36C25226B0014
What to include when you submit
- Send the bid by email to both Lynn.VanderVelde@va.gov and Ryan.McMillin@va.gov with the subject 36C25226B0014
- Price the base bid only; the RFI response says the bid alternatives in the specifications are not used
- Acknowledge receipt of each amendment before the response due date, as the amendment forms require
After award, you must have
- All contractor and subcontractor employees must follow the VA security program and be badged and identified by project and employer From S02 - Bid Specifications_20260421.pdf:
All employees of general contractor and subcontractors shall comply…
Not in the notice text
- Attached but not read: the solicitation document itself (S02 - 36C25226B0014.docx), the drawing sets (Parts 1 to 9), Addendum No. 1 and No. 2, the RFI responses in Amendments 0003 and 0005, the updated pages 3 and 11, the infection control spreadsheet, and Wage Determination WI20260011. Bid forms, bonding and award terms may be in them.
- Bonding (bid, performance and payment bonds) is not stated in the text that was read
- Which wage rule applies: Wage Determination WI20260011 is attached but not read, and Davis-Bacon is not mentioned in the read text
- Whether a site visit is required: the read text only says visits are by appointment with the COR, and the dates given are for visits that were held
- How the award is decided and whether the Government estimate is given are not stated in the read text
- Question deadline is not stated in the read text
More to check before you bid
- Not certified through VetCert yet? Apply on VetCert (SBA), or start with the SDVOSB guide. More open service-disabled veteran-owned set-asides under NAICS 238210
Notice details
Notice type, codes, versions and files
- Posted
- Aug 13, 2026
- Notice type
- Solicitation
- Office
- 252-Network Contract Office 12 (36C252), Milwaukee, WI
- Product/service code
- Z1DA · Maintenance of Hospitals and Infirmaries
- Business type
- Construction & renovation (FedReady's grouping, from NAICS 238210)
- Versions
7 versions have been posted, newest first.
- Nov 19, 2026 · Amendment 0006Due Dec 1, 2026
- Nov 5, 2026 · Amendment 0005Due Dec 1, 2026
- Oct 30, 2026 · Amendment 0004Due Dec 1, 2026 (changed)
- Oct 7, 2026 · Amendment 0003Due Nov 4, 2026 (changed)
- Sep 21, 2026 · Amendment 0002Due Oct 20, 2026 (changed)
- Sep 4, 2026 · Amendment 0001Due Sep 22, 2026
- Aug 13, 2026 · Solicitation (this version)Due Sep 22, 2026
- Attachments
Before you respond
- How to respond to a solicitation (8 steps)
- How to read a government solicitation
- How to price a government contract
- Open SDVOSB set-aside contracts
Terms on this notice: Solicitation, SDVOSB (service-disabled veteran-owned small business), Set-aside