Solicitation
Morales, TX (QNA) ARSR - Repair/Replace Building and Exterior Items to Correct Water Damage, Prevent Water Intrusion
Department of Transportation · Federal Aviation Administration
Small business set-aside · TX
A newer version of this notice was posted Nov 20, 2026. See the latest version.
AI summary Beta
Summary of another version of this notice: check what changed on SAM.gov. The notice looks incomplete: Large parts of the solicitation form, the combined specifications and the door hardware section were left out of the text read. Proposal submission method, page limits, price schedule, bond amounts, completion time and any site visit may be there. Check the attachments on SAM.gov.
Only small businesses can bid. The Federal Aviation Administration (FAA) wants a contractor to repair a radar equipment building (the ARSR building) near Morales, Texas, about 12 miles south of Hallettsville, to stop water damage and leaks. Work includes washing, sealing, door hardware and doors, ceiling tiles, flooring, painting and fans. Performance and payment bonds are required, and the response due date is December 23, 2026 at 5:00 PM Central.
Who can bid (4)
- Total small business set-aside: only small businesses can bid From 6973GH-27-R-00042.pdf
- Performance bond and payment bond required; amounts and due date are not in the text read From 6973GH-27-R-00042.pdf
- Contractor must perform work equivalent to at least 51 percent of the total amount of work on the site with its own organization From 6973GH-27-R-00042.pdf
Show all 4Show fewer
- Contractor pays for a GSA-certified locksmith to move the main entrance lock and box to the new door From 1703883 QNA ARSR Scope of Work Repair Building Morales TX 2026 Sept 22.pdf
Things to watch (8)
From the version posted Nov 20, 2026.
- Serious: Small business set-aside: only small businesses can bid. SAM.gov shows a total small business set-aside, and the solicitation carries the matching clause. A firm that is not small under NAICS 236220 cannot bid. From 6973GH-27-R-00042.pdf
- Serious: Performance and payment bonds required. You need a surety to issue both bonds. The bond amounts and when they are due are not in the text read. From 6973GH-27-R-00042.pdf
- Worth checking: Technical rejection on narrative or work plan. This is a lowest price technically acceptable award. A work plan that doesn't address every listed item is rated unacceptable and won't be considered for award. From 6973GH-27-R-00042.pdf
Show all 8Show fewer
- Worth checking: Self-perform at least 51 percent of the work on site. Your own organization must do work equal to at least 51 percent of the total amount on site, which limits how much you can subcontract. From 6973GH-27-R-00042.pdf
- Worth checking: Escorted access to the secure equipment room. FAA staff with the required clearance must escort workers inside the building, so access days may be limited. Workers may also face an FAA security investigation. From SECTION 01 01 11 Summary of Work QNA ARSR Morales TX 2026 September 22.pdf
- Worth checking: Amendment 1 added door and flooring work. Amendment 1 adds fire-rated Equipment Room doors, locksmith work and contractor-supplied flooring, with an estimated cost impact the FAA gives as $15,000. Price all of it. From 1703883 QNA ARSR Amendment 1 Repair Building Morales TX 2026 Sept 22.pdf
- Minor: Work hours and no-work periods. Regular hours are weekdays only, secure-area work may be four 10-hour days, and no work is allowed during FAA moratoriums unless waived. From SECTION 01 01 11 Summary of Work QNA ARSR Morales TX 2026 September 22.pdf
- Minor: Wage rule: Davis-Bacon wage determination TX20260158. Workers must be paid at least the listed prevailing wages under this Davis-Bacon wage determination. From 6973GH-27-R-00042.pdf
Read from the notice and 7 attachments. Show which files.
- 6973GH-27-R-00042.pdf (read)
- 1703883 QNA ARSR Specifications Combined Repair Building Morales TX 2026 Sept 22.pdf (read)
- 1703883 QNA ARSR Scope of Work Repair Building Morales TX 2026 Sept 22.pdf (read)
- 1703883 QNA ARSR Amendment 1 Repair Building Morales TX 2026 Sept 22.pdf (read)
- SECTION 01 01 11 Summary of Work QNA ARSR Morales TX 2026 September 22.pdf (read)
- SECTION 08 71 00 Door Hardware with Schedule QNA ARSR 2026 Sept 22.pdf (read)
- QNA ARSR DESIGN DRAWINGS JCN 1703883.pdf (read)
Full summary
What they want
- Power wash the whole building exterior and cable trays; apply two coats of water repellent to the exterior concrete block (CMU) walls and exposed foundation
- Remove and replace old sealant in the building's eight vertical wall control joints and other joints; repair interior gypsum board and plywood wall joints
- Replace all exterior door hardware with lever handles and all lock cylinders (BHMA Grade 1, a top durability grade, with a 7-pin removable core); add panic hardware on the Emergency Generator Room and Equipment Room doors
- Replace only the Equipment Room exterior doors and frames with 14 gauge steel, label B fire-rated doors; a GSA-certified locksmith, paid by the contractor, moves the main entrance lock and Hoffman box to the new door
- Replace damaged and mold-stained acoustical ceiling tiles (24 by 48 inch; 6 extra tiles to the FAA's representative)
- Replace vinyl composition floor tiles and 4 inch base with contractor-supplied material, as changed by Amendment 1 from government-furnished
- Paint interior walls and ceilings, exterior metal siding, doors and frames, cable trays and about 24 pipe bollards; add bollard covers
- Replace two gable attic exhaust fans and controls and one round wall fan; add wall housings and three weatherhoods; test the fans
- Place of performance
- TX, USA. Project location: about 12 miles south of Hallettsville TX (Morales).
- Estimated value
- Not stated
- How they'll choose
- Lowest priced, technically acceptable (LPTA): the lowest price among offers rated acceptable wins
- Offers due
- December 23, 2026, 5:00 PM Central (6:00 PM Eastern)
What they'll judge offers on
- Technical narrative: describes how you will accomplish the work in the statement of work, specifications and drawings; rated acceptable or unacceptable
- Work plan (Factor 2, sub-factor 2.2): what specifically you will do on each of 11 listed items, with no pricing; rated acceptable or unacceptable
- Price: lowest price among acceptable offers from a responsible offeror
What to include when you submit
- Include a work plan describing what you will do for each of the 11 items listed in the solicitation, with no pricing information in it
- General statements that work will follow the plans and specifications, without describing the work, are non-responsive and will not be considered
- Only one proposal from each offeror will be considered
- Offeror completes the solicitation form blocks 12, 16, 22, 23 and 28 (discount terms, offeror details, unit price, amount, signature)
Not in the notice text
- Large parts of the solicitation form, the combined specifications and the door hardware section were left out of the text read. Proposal submission method, page limits, price schedule, bond amounts, completion time and any site visit may be there.
- Whether there is a site visit, and whether it is required, is not stated in the text read.
- The date for questions is not stated in the text read.
- The period of performance and completion time are not stated in the text read.
- No estimated value or budget is stated.
- The design drawings were attached as images, so no drawing text was read.
Notice details
Notice type, codes, versions and files
- Posted
- Nov 20, 2026
- Notice type
- Solicitation
- Office
- 6973GH Franchise Acquisition SVCS, Oklahoma City, OK
- Product/service code
- Z2BC · Repair or Alteration of Radar and Navigational Facilities
- Business type
- Construction & renovation (FedReady's grouping, from NAICS 236220)
- Versions
3 versions have been posted, newest first.
- Nov 20, 2026 · Amendment 0002Due Dec 23, 2026
- Nov 20, 2026 · Amendment 0001 (this version)Due Dec 23, 2026
- Nov 20, 2026 · SolicitationDue Dec 23, 2026
- Attachments
Before you respond
- How to respond to a solicitation (8 steps)
- How to read a government solicitation
- How to price a government contract
- Set-aside contracts explained
Terms on this notice: Solicitation, Set-aside
Full notice text from SAM.gov
Similar open opportunities
- Renovate Building 1203-DOAS/AHU and Fire Suppression Water System, March Air Reserve Base, CaliforniaThe Army Corps of Engineers Louisville District is taking sealed bids to renovate the HVAC and fire suppression water system of Building 1203 at March Air Reserve Base,…
- Correct Electrical DeficienciesOnly service-disabled veteran-owned small businesses (SDVOSBs) can bid on solicitation 36C24627B0001, a sealed-bid construction job from the Department of Veterans Affairs (VA),…
- Project Number 657-507, Correct Seismic Deficiencies for Building 14, Marion VAMC, Illinois Construction of New Boiler Plant and Demolition of ExistingSolicitation 36C10F26R0085: only Veterans Affairs-verified service-disabled veteran-owned small businesses listed in VA's Vendor Information Pages (VIP) database can bid.
- FY27 NRM - Correct Mather Loop Road and Install Speed BumpsPresolicitation 36C26127Q0112: the VA's Network Contracting Office 21, for the VA Northern California Health Care System, plans a request for quote (RFQ) open only to…