Solicitation
USAG- Pumping and Cleaning of Grease Traps and Septic Tanks
Department of Defense · Department of the Army
HUBZone set-aside · Fort Bragg, NC
A newer version of this notice was posted Nov 19, 2026. See the latest version.
AI summary Beta
Summary of the version posted Nov 18, 2026. The notice was amended Nov 19, 2026. Check what else changed on SAM.gov. This summary may miss requirements: 2 of 6 attachments weren't read (KW 500 As-Builts.pptx, TE-1 as of 18NOV26.xlsx). Check the attachments on SAM.gov.
Only businesses certified by the Small Business Administration (SBA) as HUBZone small businesses can bid: this is a 100 percent HUBZone set-aside. The Army (Fort Bragg contracting office) wants grease traps, septic tanks and lift stations pumped and cleaned at about 139 systems or facilities at Fort Bragg, North Carolina. The response due date is November 30, 2026, 10:00 AM Eastern, but the posted answers say 11:00 AM. The contract is one base year plus four option years.
Who can bid (8)
- Be actively certified by the SBA as a HUBZone small business concern when you submit your quote; self-certification is not allowed From W91247-27-Q-A003 0001 Conformed Copy 20261117.pdf.pdf
- Be registered in the System for Award Management (SAM) before submitting a quote From W91247-27-Q-A003 0001 Conformed Copy 20261117.pdf.pdf
- Carry the required insurance (workers' compensation as required by North Carolina, employer's liability, general liability, automobile liability) and send proof with the quote From W91247-27-Q-A003 0001 Conformed Copy 20261117.pdf.pdf
Show all 8Show fewer
- Perform at least 50 percent of the personnel cost of the work with your own employees or similarly situated HUBZone firms (limitations on subcontracting, FAR 52.219-14) From W91247-27-Q-A003 0001 Conformed Copy 20261117.pdf.pdf
- Quality Control Manager with at least two years of documented relevant experience From W91247-27-Q-A003 0001 Conformed Copy 20261117.pdf.pdf
- Septic tank drivers and pumping employees with at least one year of grease trap, septic tank and lift station experience From W91247-27-Q-A003 0001 Conformed Copy 20261117.pdf.pdf
- Project Manager who meets the PWS paragraph 1.18.6 qualifications before award, with authority to act for the company and available 7:30 AM to 4:30 PM Eastern From QA - W91247-27-Q-A003 20261118 Clean copy.docx
- Up to five relevant contracts from the last three years (similar nature, size, magnitude, complexity and scope); no history is rated neutral, which counts as acceptable From W91247-27-Q-A003 0001 Conformed Copy 20261117.pdf.pdf
How to submit: Email to the Contract Specialist (luis.serrano-torres.civ@army.mil) and the Contracting Officer (john.j.machine.civ@army.mil). What to include is under Full summary below. Check the solicitation's instructions on SAM.gov.
Things to watch (11)
- Serious: HUBZone-certified businesses only. A quote from a firm without active SBA HUBZone certification is rejected at the first check and never evaluated. From W91247-27-Q-A003 0001 Conformed Copy 20261117.pdf.pdf
- Serious: Response due time differs: 10:00 AM vs 11:00 AM Eastern. SAM.gov and Section L give 10:00 AM Eastern on November 30, 2026, but the posted answers say 11:00 am; ask the contracting officer which governs, and the SF 1449 cover was also questioned. From QA - W91247-27-Q-A003 20261118 Clean copy.docx
- Serious: Strict pass/fail compliance check. Wrong file format (Word), missing volumes or any price mismatch between the Excel schedule and the SF 1449 gets the quote thrown out without further review. From W91247-27-Q-A003 0001 Conformed Copy 20261117.pdf.pdf
Show all 11Show fewer
- Worth checking: Funds not yet available. The solicitation says no award will be made until funding is available, so award timing is uncertain. From W91247-27-Q-A003 0001 Conformed Copy 20261117.pdf.pdf
- Worth checking: Key West, Florida site in a North Carolina contract. The answers add one grease trap at Naval Air Station Key West, far from Fort Bragg, which affects travel and pricing. From QA - W91247-27-Q-A003 20261118 Clean copy.docx
- Worth checking: Two-hour emergency response, no overtime. You must start emergency work within two hours of a call, yet overtime is not authorized; overtime must be built into the per-gallon rate. From W91247-27-Q-A003 0001 Conformed Copy 20261117.pdf.pdf
- Worth checking: Emergency line capped at $15,000 a year. Work above the cap may be an unauthorized commitment that needs later approval by the Contracting Officer, so you may not be paid for it. From QA - W91247-27-Q-A003 20261118 Clean copy.docx
- Worth checking: Half of personnel cost must stay in-house. Your staffing plan must show you or other HUBZone firms perform at least 50 percent of the personnel cost, which limits subcontracting. From W91247-27-Q-A003 0001 Conformed Copy 20261117.pdf.pdf
- Worth checking: Overtime not authorized. Prices must fit within regular hours at Service Contract Act wage rates; quotes with labor rates below the wage determination are rejected. From W91247-27-Q-A003 0001 Conformed Copy 20261117.pdf.pdf
- Worth checking: Part of the site list and drawings not read. Technical Exhibit #1 (the site list, in a spreadsheet) and the Key West as-builts were attached but not read, and answers say hydro-jetting line data is not available. From QA - W91247-27-Q-A003 20261118 Clean copy.docx
- Minor: No site visit. Bidders must price from the solicitation exhibits and history alone. From W91247-27-Q-A003 0001 Conformed Copy 20261117.pdf.pdf
Read from the notice and 4 attachments. 2 of 6 not read. Show which files.
- QA - W91247-27-Q-A003 20261118 Clean copy.docx (read)
- W91247-27-Q-A003 0001 20261117.pdf.pdf (read)
- W91247-27-Q-A003 0001 Conformed Copy 20261117.pdf.pdf (read)
- 15-4377 rv33 20262008.txt (read)
- KW 500 As-Builts.pptx: not read (the AI doesn't read this file type yet): open it on SAM.gov
- TE-1 as of 18NOV26.xlsx: not read (the AI doesn't read this file type yet): open it on SAM.gov
Full summary
What they want
- Pump, clean, remove grease from, inspect and dispose of waste from grease traps and septic tanks, per the performance work statement (PWS: the document that describes the work) and Technical Exhibit #1 (the list of sites and service levels)
- Service about 139 systems/facilities at Fort Bragg, plus one grease trap at Naval Air Station Key West, Florida (building KW-500, Mustin Street)
- Separate priced lines for grease traps, septic tanks, school grease traps (reimbursable) and Womack grease traps (reimbursable) in each year
- Emergency pumping on call: start work within two hours of a phone call; billed per gallon under a $15,000 not-to-exceed line each year
- Supply all labor, equipment, trucks, tools, materials and water; the Government provides no utilities
- Report all contractor labor hours in SAM.gov each fiscal year (service contract reporting line)
- Name a Project Manager and a Quality Control Manager and meet the staffing rules for drivers and pumping crews
- Contract type
- Firm-fixed-price (one set price per line, whatever the work ends up costing), with a $15,000 not-to-exceed emergency pumping line each year
- Period of performance
- Base year December 14, 2026 to December 13, 2027, plus four option years (each 12 months), plus the FAR 52.217-8 option to extend services
- Place of performance
- Fort Bragg, NC, USA; one grease trap at Naval Air Station Key West, Florida (building KW-500, Mustin Street), per the posted answers
- Estimated value
- Not stated
- How they'll choose
- Lowest priced technically acceptable (LPTA: the lowest price wins among quotes that pass), in four stages: administrative compliance check, technical capability, past performance, then price. Award is planned without discussions.
- Offers due
- November 30, 2026, 10:00 AM Eastern (from the version posted Nov 18, 2026; amended since)
- How to submit
- Email to the Contract Specialist (luis.serrano-torres.civ@army.mil) and the Contracting Officer (john.j.machine.civ@army.mil)
- Page limits
- Volume II (Technical Capability): 30 pages maximum; Volume III (Past Performance): 10 pages maximum; Volume I and Volume IV: no page limit
What they'll judge offers on
- Stage 1 Administrative Compliance Gate (pass/fail): all four volumes, correct file formats, signed SF-1449, and active SBA HUBZone certification
- Factor 1 Technical Capability (acceptable/unacceptable): (1a) Staffing and Transition Plan: staffing levels, unpriced staffing matrix, Project Manager and Quality Control Manager resumes, 50 percent limit on subcontracting; (1b) Pumping and Cleaning Service Execution Plan: execution plan, equipment maintenance plan, hazardous material plan, two-hour emergency response
- Factor 2 Past Performance (acceptable, neutral or unacceptable): up to 5 relevant contracts from the last 3 years; no history counts as neutral, which is treated as acceptable
- Factor 3 Price: completeness, accuracy, reasonableness and labor rate realism; lowest total evaluated price wins
What to include when you submit
- Send four separate volumes: Volume I General Documents, Volume II Technical Capability, Volume III Past Performance, Volume IV Price
- Volumes I, II and III must be searchable Adobe PDF; Volume IV (price schedule) must be Microsoft Excel. Microsoft Word narratives and hyperlinks are prohibited
- Volume I cover sheet: company name, address, phone and email; solicitation number W91247-27-Q-A003; Unique Entity ID (UEI) and CAGE code; name, title and phone of the person who can bind the company; whether the company has filed for bankruptcy in the last seven years
- Volume I: a completed, signed and dated Standard Form 1449 (SF 1449, the form you sign and return as your offer) with Blocks 17a, 19-24, 30a, 30b and 30c filled in, with unit and extended prices for the base year and all option years
- Volume I: list every amendment you acknowledge on the cover sheet
- Volume I: State Unemployment Tax Act (SUTA) certificate, Workers' Compensation Insurance certificate and proof of General Liability insurance; the posted answers also accept a signed officer certification in place of a SUTA certificate
- Volume II: staffing narrative, unpriced staffing matrix (labor categories, exempt or non-exempt, productive hours, full-time equivalents, and the Service Contract Act wage determination category number for each non-exempt job), resumes for the Project Manager and Quality Control Manager, and a plan to meet the 50 percent limit on subcontracting
- Volume II: pumping and cleaning execution plan covering all service areas in Technical Exhibit #1, an equipment maintenance plan, and a hazardous material plan (list, storage plan, handling procedures) that follows Army Regulation 200-1
- Volume III: no more than five relevant contracts from the last three years, each with contract number, agency and point of contact, period of performance, total value (base plus options) and a description of the pumping and cleaning work; add citations for any subcontractor doing key work
- Volume IV: priced CLIN schedule (CLIN = one priced line of the order) in Excel for the base year and all four option years, with a priced labor matrix ("show your math") that matches the SF 1449 prices exactly
- Enter a per-gallon rate on each emergency line (0005, 1005, 2005, 3005, 4005); it is not used to compare prices
- Questions are by email to the same two contacts
Current contractor
The posted answers name the incumbent as The Plumbing Shop Inc. dba Quick Action Group (QAMG), contract IGSA NC-R5-HVAC-090524, firm-fixed-price, June 1, 2026 to December 1, 2026, total contract value $512,000.00. They also refer to an earlier contract W91247-20-P-0032. The answers say the Technical Exhibit has been about the same for two years.
Not in the notice text
- The PWS (Performance Work Statement - Clean Copy 20261028, listed in Section J) was not in the text provided, and Technical Exhibit #1 (TE-1 as of 18NOV26.xlsx) and KW 500 As-Builts.pptx were attached but not read; check them on SAM.gov for the full service list, frequencies, per-site details and PM rules
- The Government's estimate or total contract value is not stated; the incumbent's $512,000.00 is a past contract's value
- Hydro-jetting line lengths, diameters and access details are not available, per the posted answers
- The posted answers say performance starts December 14, 2026 with no separate mobilization period; the award date is not stated
More to check before you bid
Notice details
Notice type, codes, versions and files
- Posted
- Nov 18, 2026
- Notice type
- Solicitation
- Office
- W6QM MICC FDO FT Bragg, Fort Bragg, NC
- Product/service code
- S222 · Housekeeping – Waste Treatment/Storage
- Business type
- Environmental & natural resources (FedReady's grouping, from NAICS 562991)
- Versions
6 versions have been posted, newest first.
- Nov 19, 2026 · Amendment 0005Due Nov 30, 2026
- Nov 18, 2026 · Amendment 0004 (this version)Due Nov 30, 2026
- Nov 18, 2026 · Amendment 0003Due Nov 30, 2026
- Nov 3, 2026 · Amendment 0002Due Nov 30, 2026
- Nov 3, 2026 · Amendment 0001Due Nov 30, 2026
- Nov 2, 2026 · SolicitationDue Nov 30, 2026
- Attachments
Before you respond
- How to respond to a solicitation (8 steps)
- How to read a government solicitation
- How to price a government contract
- Open HUBZone set-aside contracts
Terms on this notice: Solicitation, HUBZone, Set-aside
Full notice text from SAM.gov
Similar open opportunities
- BPA Setup - Waste Removal and disposal from Vault toilets & Septic tanks at various sites for the Region 6 National ForestThe USDA Forest Service (Pacific Northwest, Region 6) wants small businesses to set up a blanket purchase agreement for pumping out and disposing of waste from vault toilets, pit…
- ACW (Ava-Cassville-Willow Springs Ranger District, Mark Twain National Forest) Toilet PumpingThe Forest Service wants a small business to pump vault toilets at 9 recreation sites on the Ava-Cassville-Willow Springs Ranger District, Mark Twain National Forest, in southern…
- KFO Vault Toilet PumpingThe Bureau of Land Management (BLM, Interior Department) wants vault toilet pumping at recreation sites in the Kemmerer Field Office in Wyoming, on solicitation 140LL027Q0021.
- Grease Trap Service-FY27 Base-Tomah VAMC - December 2026 - November 2027Solicitation 36C25227Q0069: the Department of Veterans Affairs (VA), Network Contract Office 12, wants grease traps cleaned at the Tomah VA Medical Center in Tomah, Wisconsin.
- Tank and Parts Washer Cleaning and Desludging ServicesThe Navy's Mid-Atlantic Regional Maintenance Center wants tank and parts washer cleaning and desludging services (removing sludge from washing tanks).