Combined Synopsis/Solicitation
Medical Air & Vacuum Compressors Replacement Service
Department of Veterans Affairs
AI summary Beta
The notice looks incomplete: Part of the main solicitation PDF (about 6,000 characters, in the middle of the offer instructions and provisions) was attached but not read; check it on SAM.gov for any other submission rules. Check the attachments on SAM.gov.
The Department of Veterans Affairs (VA) Network Contracting Office 22 wants to replace one medical air compressor and two medical vacuum compressors in Buildings 148 and 160 at the Northern Arizona VA Healthcare System in Prescott, AZ. The work includes new wiring, a full medical gas inspection and certification, and as-built drawings, all within one year of award. SAM.gov doesn't state a set-aside, but an attached notice form lists the set-aside as SDVOSBC. The response due date is December 11, 2026, 3:00 PM Mountain.
Who can bid (7)
- Set-aside listed as SDVOSBC on the attached notice form (SAM.gov lists no set-aside). It appears to mean service-disabled veteran-owned small business; confirm with the contracting officer who can bid. From RFQ Contract Opp 36C26227Q0065.pdf
- Prime contractor must have completed NFPA 99C Medical Gas Certifier training and provide a current certificate of qualification. From S02 RFQ Medical Air and Vacuum Compressor replacement 36C26227Q0065.pdf
- Installers must be certified to ASSE 6010, inspectors to ASSE 6020 and verifiers to ASSE 6030. Certificates are shown on arrival, before the certification process. From S02 RFQ Medical Air and Vacuum Compressor replacement 36C26227Q0065.pdf
Show all 7Show fewer
- Installers, verifiers and inspectors must come from different companies, whether prime or subcontractor. From S02 RFQ Medical Air and Vacuum Compressor replacement 36C26227Q0065.pdf
- Registration with the VA financial system, with email confirmation included in the offer. From S02 RFQ Medical Air and Vacuum Compressor replacement 36C26227Q0065.pdf
- Signed 852.219-75 VA Limitations on Subcontracting certificate returned with the offer. From S02 RFQ Medical Air and Vacuum Compressor replacement 36C26227Q0065.pdf
- Experience on at least two prior contracts in healthcare medical gas compressor, vacuum, oxygen tank and alarm panel replacement or repair. From S02 RFQ Medical Air and Vacuum Compressor replacement 36C26227Q0065.pdf
How to submit: Email to kyle.cipra@va.gov, with a cover letter. What to include is under Full summary below. Check the solicitation's instructions on SAM.gov.
Things to watch (7)
From the version posted Nov 18, 2026.
- Serious: Set-aside shown as SDVOSBC in the attachment; SAM.gov states none. SAM.gov says no set-aside, but the attached notice form lists SDVOSBC, so a business that is not a service-disabled veteran-owned small business should confirm eligibility before bidding. From RFQ Contract Opp 36C26227Q0065.pdf
- Serious: Medical gas certifications and separate companies. The prime needs NFPA 99C certifier training, and installers, verifiers and inspectors (ASSE 6010, 6020, 6030) must be three different companies, so you must line up qualified partners before bidding. From S02 RFQ Medical Air and Vacuum Compressor replacement 36C26227Q0065.pdf
- Serious: Offer left out of consideration without two forms. The VA financial system registration confirmation and the signed limitations on subcontracting certificate must go in with the offer, or the offer may not be considered. From S02 RFQ Medical Air and Vacuum Compressor replacement 36C26227Q0065.pdf
Show all 7Show fewer
- Worth checking: Tight shutdown windows in a working hospital. Each shutdown must finish within three days, avoid weekends and holidays, and be coordinated with staff, adding scheduling cost and risk. From S02 RFQ Medical Air and Vacuum Compressor replacement 36C26227Q0065.pdf
- Worth checking: Backup oxygen system required. If a repair takes more than eight hours, the contractor must supply backup oxygen Dewar tanks with a manifold and alarm, which adds cost. From S02 RFQ Medical Air and Vacuum Compressor replacement 36C26227Q0065.pdf
- Minor: Work hours limited. Work is allowed only on weekdays, 8:00 AM to 4:00 PM, excluding federal holidays; weekend work needs a written request. From S02 RFQ Medical Air and Vacuum Compressor replacement 36C26227Q0065.pdf
- Minor: One price line, five work lines. The SF 1449 price schedule shows a single item 0001 (1.00 JB) while the statement of work lists CLINs 001 to 005, so ask how to price them.
Read from the notice and 3 attachments. Show which files.
- S02 RFQ Medical Air and Vacuum Compressor replacement 36C26227Q0065.pdf (read)
- RFQ Contract Opp 36C26227Q0065.pdf (read)
- S02 RFQ Medical Air and Vacuum Compressor replacement title.docx (read)
Full summary
What they want
- Replace the medical air compressor in Building 160 (CLIN 001: one air compressor, a Powerex unit)
- Replace two medical vacuum compressors, one in Building 160 (Powerex) and one in Building 148 (EMSE) (CLIN 002)
- Replace deteriorated compressor wiring and network cabling, using existing raceways, conduits and boxes (CLIN 003)
- Complete medical gas inspection, testing and certification of the whole medical gas system, including master and area alarms, with a report (CLIN 004)
- Provide as-built drawings of the medical gas system in PDF and CAD when the contract ends (CLIN 005)
- Finish any shutdown work within three days, not over weekends or holidays, and provide backup oxygen tanks (Dewars) if a repair takes longer than eight hours
- Use separate companies for installers, verifiers and inspectors, each with the required certificates
- Contract type
- Firm-fixed-price (FFP): one set price, whatever the work ends up costing
- Period of performance
- Deliverables, installation and repairs must be completed within one year of award. Option clauses allow extensions of up to 6 months for services, and total duration, including extensions, may not exceed one year.
- Place of performance
- Northern Arizona VA Healthcare System, 500 N. Highway 89, Prescott, AZ 86313, Buildings 148 and 160
- Estimated value
- Not stated
- How they'll choose
- One contract to the offer most advantageous to the Government under simplified (FAR Part 13) comparative evaluation. Evaluation starts with the lowest-priced offer, which is checked against available funding and for price reasonableness, then the offeror's responsibility. If it can't be awarded, the next lowest-priced offer is checked.
- Offers due
- December 11, 2026, 3:00 PM Mountain (MST)
- How to submit
- Email to kyle.cipra@va.gov, with a cover letter
What they'll judge offers on
- Price: total cost, checked to be fair and reasonable
- Past performance: satisfactory performance information from PPIRS and FAPIIS (a neutral rating if none is found)
- Experience: list of at least two prior contracts replacing or repairing medical gas compressor systems, vacuum systems, oxygen tanks and medical alarm panels in a healthcare setting
What to include when you submit
- Send one offer that addresses all requirements, with a cover letter, by the response due date and time in Block 8 of the Standard Form 1449 (SF 1449, the form you sign and return as your offer)
- Label the offer with the firm's name and business address, the solicitation number, and a point of contact with name, telephone and email
- No zip files and no fax offers
- Include email confirmation that you registered with the VA financial system through the Customer Engagement Portal (form 10091 webform at cep.fsc.va.gov)
- Include the completed, signed 852.219-75 VA Notice of Limitations on Subcontracting Certificate of Compliance, paragraph (d)
- Send a list of at least two prior contracts: contract number, dates of service, awarding agency, description of services, and point of contact name, phone and email
- Prices must be held firm for 60 days from the date offers are received
- Send written questions to kyle.cipra@va.gov by 3:00 PM MST, December 4, 2026
Not in the notice text
- Part of the main solicitation PDF (about 6,000 characters, in the middle of the offer instructions and provisions) was attached but not read; check it on SAM.gov for any other submission rules
- Whether there is a site visit is not stated
- The Government's estimated value is not given
- Who may bid: SAM.gov states no set-aside, while the attached notice form says SDVOSBC
- The text of the Service Contract Act wage determination 2015-5465 (Revision 32) is not included; it is on SAM.gov
- Start date or award date is not stated
Notice details
Notice type, codes, versions and files
- Posted
- Nov 18, 2026
- Notice type
- Combined Synopsis/Solicitation
- Office
- 262-Network Contract Office 22 (36C262), Gilbert, AZ
- Product/service code
- J065 · Maint/Repair/Rebuild of Equipment – Medical, Dental, and Veterinary Equipment and Supplies
- Business type
- Manufactured parts & equipment (FedReady's grouping, from NAICS 333912)
- Attachments
Before you respond
- How to respond to a solicitation (8 steps)
- How to read a government solicitation
- How to price a government contract
Terms on this notice: Solicitation
Full notice text from SAM.gov
Similar open opportunities
- Gallup Indian Medical Center - Air Compressor System Demo and ReplacementThis is a sources sought notice (market research only, not a request for quotes) from the Indian Health Service, Navajo Area, for Gallup Indian Medical Center in Gallup, NM. It…
- Parts Kit, CompressorThe Defense Logistics Agency (DLA) Weapons Support is asking for quotes on PARTS KIT,COMPRESSOR, national stock number (NSN: the government's part ID) 4310016818723, under…
- Breathing Air CompressorThe Department of the Army (MICC-Fort Drum contracting office) wants quotes on a breathing air compressor, under solicitation W911S227U0160.
- The procurement, delivery, installation, testing, and commission of a 20 HP Rotary Screw Air Compressor with Integrated Dryer System 120 GALThe U.S. Army Corps of Engineers, Tulsa District wants quotes from small businesses to supply, remove and install a 120-gallon, 20-horsepower air compressor at the RS Kerr…
- Vacuum Relief FurnaceThe Air Force's Arnold Air Force Base procurement office (AEDC) wants one new horizontal front-loading, internal gas quench vacuum heat treating and brazing furnace, QTY 1 Each,…