Solicitation
Fire Suppression System Maintenance and
Department of Veterans Affairs
AI summary Beta
Some details are in the notice's attachments, which this summary didn't read. Check the attachments on SAM.gov.
The Department of Veterans Affairs (VA) Network Contract Office 10 is buying fire suppression system maintenance, with places of performance listed only as IN. This version of the notice holds the Government's answers to bidder questions, not the full solicitation. Monthly inspections are removed, leaving semiannual maintenance and certification. The response due date is December 8, 2026, 10:00 AM Eastern.
Things to watch (4)
From the version posted Nov 24, 2026.
- Worth checking: Monthly inspections removed. The performance work statement (PWS) still mentions monthly inspections in places, but the Government says to disregard them, so price only the semiannual work.
- Worth checking: Site visit to assess conditions. The Government tells bidders to judge existing conditions themselves at a scheduled site visit; the date and whether it is required are not in this text.
- Minor: Possible pre-existing deficiencies. A bidder asked about duct-access problems; the VA says it is not aware of any, so unpriced repair risk may remain.
Show all 4Show fewer
- Minor: Revised PWS wording to be issued. The Government says the Section 10 reporting language should be revised, so check the revised PWS for the final wording.
Read from the notice text only.
Full summary
What they want
- Semiannual maintenance and certification of fire suppression systems (10 systems in the questions)
- Maintenance on Kidde dry-chemical systems, including the six-year maintenance work
- Update the equipment inventory, service log and deficiency log with each service report
- Report required services not completed, the reasons and proposed completion dates
- Handle new deficiencies through Contracting Officer-authorized corrective work under PWS Section 9
- Place of performance
- IN (state abbreviation as given on SAM.gov); no town or facility named in this text
- Estimated value
- Not stated
- Offers due
- December 8, 2026, 10:00 AM Eastern
Not in the notice text
- The solicitation, PWS, contract type, base and option periods, and submission instructions are not in this text; they are in the notice's attachments
- The set-aside is not stated on SAM.gov
- The place of performance is given only as IN; the facility and town are not stated
- The site visit date and whether it is required are not stated
- The evaluation method is not stated
More to check before you bid
- Service contracts usually set minimum pay rates (the Service Contract Act). Price the labor with the SCA price calculator.
Notice details
Notice type, codes, versions and files
- Posted
- Nov 24, 2026
- Notice type
- Solicitation
- Office
- 250-Network Contract Office 10 (36C250), Dayton, OH
- Product/service code
- J012 · Maint/Repair/Rebuild of Equipment – Fire Control Equipment
- Business type
- Equipment repair & maintenance (FedReady's grouping, from NAICS 811310)
- Versions
6 versions have been posted, newest first.
- Nov 24, 2026 · Amendment 0004 (this version)Due Dec 8, 2026
- Nov 19, 2026 · Amendment 0003Due Dec 8, 2026
- Nov 19, 2026 · Amendment 0002Due Dec 8, 2026 (changed)
- Nov 6, 2026 · Amendment 0001Due Dec 1, 2026
- Nov 6, 2026 · SolicitationDue Dec 1, 2026
- Nov 6, 2026 · PresolicitationDate Dec 1, 2026
- Attachments
Before you respond
- How to respond to a solicitation (8 steps)
- How to read a government solicitation
- How to price a government contract
Terms on this notice: Solicitation
Full notice text from SAM.gov
1. Monthly Fire Suppression Inspections PWS Sections 5, 6.1, and Appendix B The revised PWS shows Section 6.1 (Monthly Inspections) and the corresponding monthly inspection requirement in Appendix B as struck through. However, Sections 1 and 5 and Appendix A still reference monthly inspections. Could the Government please confirm whether the requirement for monthly inspections of all 10 fire suppression systems (120 inspections annually) has been officially removed, leaving only the semiannual maintenance and certification requirements? Leaving these references in was an error. All references to monthly inspections should be disregarded, as they are no longer required. 2. Monthly Reconciliation and Deficiency Log PWS Section 10 and Appendix B The revised Appendix B shows the monthly reconciliation and deficiency log deliverable as struck through, while Section 10 continues to require monthly reconciliation by the fifth business day of the following month. Could the Government confirm whether monthly reconciliation reports are still required, or whether this reporting obligation has been removed? We understand that service-specific deficiency reporting remains applicable. Section 10 is not referencing monthly inspections. It is references service reports. Since work is not being done monthly, the language should be revised to say, With each service report, the Contractor shall update the cumulative equipment inventory, service log, and deficiency log. Identify required services that were not completed, the reasons, and proposed completion dates. Update open deficiencies when corrective work is completed. A combined visit may satisfy multiple required activities only when each activity and its results are separately documented. A separate monthly reconciliation report is not required. 3. Existing Deficiencies and Six-Year Cylinder Maintenance PWS Section 9 The historical kitchen exhaust cleaning reports identify inaccessible duct sections, recommended access-panel installations, and other conditions requiring corrective action. Additionally, the October 2026 fire suppression inspection records identify six-year maintenance concerns affecting the Kidde dry-chemical systems, while the November 2026 maintenance documentation appears to address four cylinders. Could the Government please clarify: Whether the identified duct-access deficiencies will be corrected before the new contract begins or addressed separately through Contracting Officer-authorized corrective work. Whether the six-year maintenance requirements have been fully completed for all five Kidde IND-21 systems, or whether any outstanding work remains. Whether any unresolved pre-existing deficiencies should be excluded from recurring fixed-price services and handled through separate authorization under Section 9. The Six-Year maintenance deficiency was corrected on November 19th, 2026. The VA is not aware of any duct-access deficiencies, this was not listed in the previous report to the one you referenced and may be an administrative error. Offeror should make their own assessment during a scheduled site visit.
Similar open opportunities
- Dry-Type Fire Suppression SystemSources sought notice 36C26127Q0169 from the Department of Veterans Affairs (Network Contracting Office 21): the VA Palo Alto Health Care System wants to find firms that can…
- Fire Extinguisher Inspection, Maintenance, Recharge, Repair, Hydrostatic TestingOpen to all businesses (no set-aside), solicitation W5S09H27QA991 asks for a single 5-year blanket purchase agreement (BPA: a standing deal where the buyer orders as needed…
- USCG Station Fire Island Attic VentsThe U.S. Coast Guard (Base Boston) wants a contractor to replace four attic exhaust fans and their controls at Station Fire Island in Babylon, NY (solicitation 30199PR270000005).
- Vance AFB and Kegelman AAF Fire Extinguisher BPAThe Department of the Air Force (71st Flying Training Wing contracting office), solicitation FA302927Q0002, wants several firms on a multiple-award blanket purchase agreement…
- FY 27 Fire Department Trainer Maintenance & Winterization/De-WinterizationThe Air Force's 5th Contracting Squadron wants a business to inspect, test, maintain, winterize and repair three live-fire fire training trainers at Minot Air Force Base, North…