Presolicitation
Fall Protection Annual Inspection
Department of Defense · Department of the Air Force
Response due Dec 4, 2026 · Notice says small business set-aside · Tinker AFB, OK
Advance notice of a coming solicitation, not a bid yet. If it asks for capability statements, sending one is free and puts you on Department of the Air Force's list before the solicitation is posted. See the contact
A newer version of this notice was posted Nov 20, 2026. See the latest version.
AI summary Beta
Summary of another version of this notice: check what changed on SAM.gov. This summary may miss requirements: 1 of 6 attachments weren't read (FA812527Q0015 Solicitation.pdf). Check the attachments on SAM.gov.
Total small business set-aside: the Air Force wants yearly hands-on inspection and re-certification of fall protection systems (anchors, rigid rails, self-retracting lifelines) at Tinker Air Force Base, Oklahoma, for one base year plus four option years. The response due date is December 4, 2026, 12:00 PM Central (1:00 PM Eastern). Bidders must send a sample inspection report and proof that the inspector is a qualified person.
Who can bid (4)
- Total small business set-aside: only small businesses can bid (NAICS 541990). From SAM.gov's set-aside field
- Inspector must be a Qualified person under 29 CFR 1910.140(b), shown by certificates, degree, manufacturer authorization or an experience portfolio submitted with the quote. From Annual Fall Protection Inspection -PWS.pdf
- Sample inspection report covering all six system types, submitted with the quote From Annual Fall Protection Inspection -PWS.pdf
Show all 4Show fewer
- CAGE code entered in Block 17a
How to submit: Not stated in the text read. The notice says to return the completed Standard Form 1449 (SF 1449: the form you sign and return as your offer); the solicitation itself was a scan that could not be read.. What to include is under Full summary below. Check the solicitation's instructions on SAM.gov.
Things to watch (10)
From the version posted Nov 20, 2026.
- Serious: SAM.gov and the solicitation disagree on the set-aside. SAM.gov lists no set-aside, but the solicitation the AI read says a set-aside for small businesses. Ask the contracting officer which applies before you bid.
- Serious: Sample report and inspector proof due with the quote. A quote without the sample inspection report and qualification proof may be rated down or rejected, so prepare them before the response due date. From Annual Fall Protection Inspection -PWS.pdf
- Serious: Solicitation form could not be read. The main solicitation (pricing schedule, evaluation clause, clauses) is a scan with no readable text. Review it on SAM.gov before pricing.
Show all 10Show fewer
- Worth checking: Large boom lift with three moves at contractor expense. You must supply a lift reaching 125 feet and pay for transport, safety oversight and spotters for at least three moves. From Annual Fall Protection Inspection -PWS.pdf
- Worth checking: Many facilities are not ready in the base year. Some Appendix A lines show Not Ready in the base year and activate in later option years. Government can shift these dates by modification. From Annual Fall Protection Inspection -PWS.pdf
- Worth checking: System count can change by up to 40. The Government can add or remove up to 40 systems during any performance period at the agreed unit prices.
- Worth checking: Building numbers are hidden until award. The public Appendix A uses facility letters; actual building numbers come only after award, which makes travel and lift planning harder to price. From Annual Fall Protection Inspection -PWS.pdf
- Worth checking: Facility B inspection deadline in the base year. Facility B must be inspected out of cycle by January 29, 2027, and again in the June window. From Annual Fall Protection Inspection -PWS.pdf
- Minor: Service Contract Act wage rates apply. Wage Determination 2015-5315, Revision 31, for Oklahoma is attached, so labor must be priced at or above those rates. From Wage Determination 2015-5315 Rev.31_12Aug2026.pdf
- Minor: Base access, training and flight line rules. Staff need visitor passes, on-base driver and foreign object damage training, and may work up to 24/7 with a government escort on non-standard hours. From Annual Fall Protection Inspection -PWS.pdf
Read from the notice and 5 attachments. 1 of 6 not read. Show which files.
- Annual Fall Protection Inspection -PWS.pdf (read)
- Attachment 1 - Facility B Certification - Redacted.pdf (read)
- Annual Fall Protection Inspection - Appendix C High Risk.pdf (read)
- Annual Fall Protection Inspection -Appendix A.pdf (read)
- Wage Determination 2015-5315 Rev.31_12Aug2026.pdf (read)
- FA812527Q0015 Solicitation.pdf: not summarized: open it on SAM.gov
Full summary
What they want
- One hands-on annual inspection of each listed fall protection system (QTY 1 EA for most lines; QTY 2 EA in the base year for the Facility B lines)
- One re-certification of each system by a Qualified Person during the June inspection window of the base year
- An out-of-cycle baseline inspection of Facility B, then a second Facility B inspection in the June window
- Provide a boom lift reaching at least 125 feet and plan at least three moves of it
- Lock out or tag any failed equipment, give written repair estimates, and do repairs only after written contracting officer approval
- Deliver inspection certificates, service reports and inspection schedules on the PWS timelines
- Follow Tinker AFB safety, environmental, security and driver training rules
- Contract type
- Not stated in the text read; the PWS refers to unit prices per system and Over and Above repairs. The solicitation form itself was a scan that could not be read.
- Period of performance
- 1 base year + 4 option years
- Place of performance
- Tinker AFB, OK, USA (Oklahoma City Air Logistics Complex)
- Estimated value
- Not stated
- Offers due
- December 4, 2026, 12:00 PM Central (1:00 PM Eastern)
- How to submit
- Not stated in the text read. The notice says to return the completed Standard Form 1449 (SF 1449: the form you sign and return as your offer); the solicitation itself was a scan that could not be read.
What they'll judge offers on
- Technical: written statement of how the company will meet the technical evaluation criteria in FAR 52.212-2
- Technical: sample inspection report covering the six system types in the PWS
- Technical: proof that the inspector is a qualified person
- Price: unit prices for each line
What to include when you submit
- Fill in company name, address and CAGE code in Block 17a of the SF 1449.
- Sign the SF 1449 with the signer's name, title and date in blocks 30a, 30b and 30c.
- Enter pricing starting on page 3 of the solicitation, with the net amount.
- Complete any fill-in provisions and clauses.
- Include a written statement explaining how you will meet the technical evaluation criteria in FAR 52.212-2.
- Include a sample inspection report showing sample results for an anchorage, anchorage extension, single-point anchor, rigid rail fall arrest system, self-retracting lifeline and horizontal lifeline system.
- Include proof of the inspector's qualification: professional certifications, academic credentials, manufacturer certifications, or a technical experience portfolio.
- Bid unit prices for each Appendix A line; deferred facilities are bid only in the option year they activate.
- Send questions in writing two days before the closing date on page 1 of the solicitation.
After award, you must have
- Safety and Health Plan due within 10 days of award; no on-site work before the contracting officer approves it From Annual Fall Protection Inspection - Appendix C High Risk.pdf:
1. Not more than 10 days after contract award, the contractor shall submit a Safety and…
Current contractor
No incumbent is named. The PWS says Facility B has a historical certification package, but other facilities have no active certification data on file within the past five years.
Not in the notice text
- The solicitation itself (SF 1449, pricing schedule, evaluation clause, other clauses) is a scan that could not be read; check it on SAM.gov. Attachment 1, the Facility B certification, is protected and could not be opened.
- Evaluation method and the order of importance of the factors are not given in the text read.
- How to submit the quote (email address or portal) is not stated in the text read.
- Whether there is a site visit is not stated in the text read.
- The notice does not say whether the work can be done remotely.
- Appendix A uses facility letters; actual building numbers come only after award.
More to check before you bid
- The notice names requirements:
- The notice text says this is set aside for small businesses, but SAM.gov lists no set-aside. Ask the contracting officer which one applies before you bid.
Notice details
Notice type, codes, versions and files
- Posted
- Nov 19, 2026
- Notice type
- Presolicitation
- Office
- FA8125 AFSC PZIMA, Tinker AFB, OK
- Product/service code
- J049 · Maint/Repair/Rebuild of Equipment – Maintenance and Repair Shop Equipment
- Business type
- Consulting & professional services (FedReady's grouping, from NAICS 541990)
- Versions
2 versions have been posted, newest first.
- Nov 20, 2026 · SolicitationDue Dec 4, 2026
- Nov 19, 2026 · Presolicitation (this version)Date Dec 4, 2026
- Attachments
Before you respond
Terms on this notice: Solicitation
Full notice text from SAM.gov
Similar open opportunities
- FY27- Tank Inspection Ft. HOOD (Fort Hood, TX)The U.S. Army (Omaha Engineer District) wants one API 653 internal inspection (American Petroleum Institute standard for inspecting storage tanks) on facility 88070 at Ft.
- Dugway Proving Grounds Tank InspectionsThe U.S. Army (Omaha Engineer District) wants two API 653 internal inspections (American Petroleum Institute standard for inspecting storage tanks) on facilities 4056 and 4057 at…
- Vandenberg SFB Tank Inspection
- FY27 Cathodic Protection Inspection and TestingThis is a sources sought notice (market research, not a solicitation), 36C24827Q0143, from the Department of Veterans Affairs, Network Contracting Office 8, for the Orlando VA…