Solicitation
FY 27 Fire Department Trainer Maintenance & Winterization/De-Winterization
Department of Defense · Department of the Air Force
Small business set-aside · Minot AFB, ND
AI summary Beta
This summary may miss requirements: 3 of 12 attachments weren't read (Quote Sheet FD winterization .xlsx, Helo 0-100_ Hose Line Fire_ Multi Control System_ Op AND Maint. Manuals.pdf and 1 more). Check the attachments on SAM.gov.
The Air Force (5 CONS, for the 5th Civil Engineer Squadron) wants a small business to maintain three live-fire fire trainers at Minot Air Force Base, North Dakota (FA452827Q0005). Total small business set-aside, firm-fixed-price (FFP: one set price, whatever the work costs): a base year starting March 1, 2027, then four yearly periods priced as options. Written authorization from the trainer maker, KFT Fire Trainer, LLC, is required. The response due date is November 27, 2026, 3:00 PM Central.
Who can bid (6)
- Small business under the $12,500,000 size standard for NAICS 811310; this is a total small business set-aside on SAM.gov
- Current registration in the System for Award Management (SAM) before you submit a quote; SAM is checked before any evaluation From Instructions to Offerors.pdf
- Written documentation from the maker (KFT Fire Trainer, LLC, formerly Kidde Fire Trainers) that you are certified and authorized to service its products From 10 November 26 PWS Fire Department Trainer Maintenance .pdf
Show all 6Show fewer
- Technicians certified by the maker as Level 3 maintainers for unsupervised work, and a certified maker Level 4 Service Specialist to verify the safety systems From 10 November 26 PWS Fire Department Trainer Maintenance .pdf
- State or local liquid petroleum gas (LPG) or gas fitter licenses for technicians who service gas piping, vaporizers, regulators or valves From 10 November 26 PWS Fire Department Trainer Maintenance .pdf
- At least three years of experience inspecting and maintaining fire trainer or similar systems, with proof From 10 November 26 PWS Fire Department Trainer Maintenance .pdf
How to submit: Email to Sherry L. Platt (sherry.platt.1@us.af.mil) and Contracting Officer Theodore Arneson (theodore.arneson@us.af.mil). What to include is under Full summary below. Check the solicitation's instructions on SAM.gov.
Things to watch (10)
From the version posted Nov 10, 2026.
- Serious: Maker authorization and certified technicians required. Only firms with written authorization from KFT Fire Trainer, LLC, and technicians certified by the maker can do this work, which may rule out most small businesses. From 10 November 26 PWS Fire Department Trainer Maintenance .pdf
- Serious: Gas fitter licenses required. Technicians who service the gas piping and valves must hold state or local LPG or gas fitter licenses, and the Technical Capability factor checks them. From 10 November 26 PWS Fire Department Trainer Maintenance .pdf
- Serious: Redacted copy of the quote required. Two copies are needed, one with all company and personal information removed; leaving it out can get a quote disqualified. From Instructions to Offerors.pdf
Show all 10Show fewer
- Worth checking: Three years of experience, with proof. The prime must show at least three years inspecting and maintaining fire trainers or similar systems, with resumes and certifications sent with the quote. From 10 November 26 PWS Fire Department Trainer Maintenance .pdf
- Worth checking: Fixed seasonal work windows. Winterization and de-winterization must fall inside set dates each year, and inspections may be no more than 240 calendar days apart. From 10 November 26 PWS Fire Department Trainer Maintenance .pdf
- Worth checking: Emergency visit within 48 hours. A technician must be on site within 48 hours of notice, which is hard for a firm based far from North Dakota. From 10 November 26 PWS Fire Department Trainer Maintenance .pdf
- Worth checking: Five-year structural inspection in fiscal year 2029. A licensed structural engineer, or a professional with 10 years of structural evaluation experience, must certify the structural trainer once during the option year for fiscal year 2029. From 10 November 26 PWS Fire Department Trainer Maintenance .pdf
- Minor: Repairs are not priced up front. Repair lines are not quoted; the Contracting Officer approves each repair after a written estimate, so repair income is not guaranteed. From 10 November 26 PWS Fire Department Trainer Maintenance .pdf
- Minor: Extension dates leave a gap after the last option year. The last yearly period ends February 29, 2032, but the extension lines run March 1, 2033 to August 31, 2033; ask the contracting officer which dates apply. From Solicitation - FA452827Q0005.pdf
- Minor: Questions were due Nov 19, 2026. Check the amendments for the agency's answers. From Instructions to Offerors.pdf
Read from the notice and 9 attachments. 3 of 12 not read. Show which files.
- Solicitation - FA452827Q0005.pdf (read)
- Instructions to Offerors.pdf (read)
- TO 35E1-2-13-1 Technical Manual Operation and Maintenance Instructions .pdf (read)
- 10 November 26 PWS Fire Department Trainer Maintenance .pdf (read)
- 10 November 2026 DAF Clauses.pdf (read)
- Past and Present Performance Questionnaire.docx (read)
- Minot AFB_T500 OM Manual_5-29-2026.pdf (read)
- Base Hazardous Waste Management Plan .pdf (read)
- Wage Determination No._ 2015-5383 Date of Last Revision_ 12_23_2024.pdf (read)
- Quote Sheet FD winterization .xlsx: not read (the AI doesn't read this file type yet): open it on SAM.gov
- Helo 0-100_ Hose Line Fire_ Multi Control System_ Op AND Maint. Manuals.pdf: not read (it couldn't be opened): open it on SAM.gov
- Minot O100 Manuals.pdf: not read (it couldn't be opened): open it on SAM.gov
Full summary
What they want
- Two semi-annual inspections a year of the aircraft, structural and helicopter fire trainers, following technical order TO 35E1-2-13-1 and the maker's manuals
- Winterization between September 20 and September 29, and de-winterization between April 15 and May 1
- Repairs approved one by one after a written cost estimate; on-site emergency visit within 48 hours of notice; phone support Monday to Friday, 7:00 AM to 5:00 PM Central
- Written reports within 5 business days of inspections and seasonal work, within 3 business days of repairs, and a signed safety certification before a trainer returns to use
- Yearly written safety-modification documentation from the maker; a unit without it in 18 months is shut down
- One structural integrity inspection of the structural trainer in the option year for fiscal year 2029, with a report within 10 calendar days
- After award: 30-day phase-in (base passes, Quality Control Plan, Safety Data Sheets), and authorization letters, licenses and resumes sent within 10 days
- Keep maintenance records for 3 years; send a hazardous material list at least 15 calendar days before bringing any onto the base
- Contract type
- Firm-fixed-price (FFP), request for quotation; simplified acquisition procedures
- Period of performance
- Base year March 1, 2027 to February 29, 2028, then four yearly periods (CLIN groups 1000 to 4000) through February 29, 2032, plus extension-of-services lines (5001 to 5003) dated March 1, 2033 to August 31, 2033
- Place of performance
- Minot Air Force Base, ND (Fire Department Training Area, Bldg. 2226 Bomber Blvd.)
- Estimated value
- Not stated
- How they'll choose
- Best value: the award goes to the quote most advantageous to the Government, price and other factors considered. Price is evaluated as the total of the base and all option prices
- Offers due
- November 27, 2026, 3:00 PM Central
- How to submit
- Email to Sherry L. Platt (sherry.platt.1@us.af.mil) and Contracting Officer Theodore Arneson (theodore.arneson@us.af.mil)
What they'll judge offers on
- Price: total evaluated price, a total firm-fixed-price quote that is fair, reasonable and balanced, with option prices added to the base
- Technical Capability (must be rated acceptable): technicians must prove the required commercial licenses, manufacturer-specific certifications and safety training for live-fire and gas systems
- Past Performance: up to three efforts from the last three years; maintaining similar simulator systems for other DoD bases, municipal airports or municipal fire departments
What to include when you submit
- Fill in the Quote Sheet attachment entirely; do not quote the repair lines, which are priced later per approved repair
- Send two copies: the original and a redacted copy with all company and personal names and logos removed; failing to send the redacted copy may mean disqualification
- Fill in the contractor identification block: company name, contact, address, SAM registered, small business, UEI, CAGE, veteran-owned, woman-owned, signature and date
- Include a certificate of compliance with resumes and certifications showing the prime has at least three years of experience inspecting and maintaining fire trainer or similar systems
- Show your technicians hold the required commercial licenses, manufacturer-specific certifications and safety training for live-fire and gas systems
- Send up to three past performance documents; recency means active or completed work in the three years before the solicitation was issued; the Past & Present Performance Questionnaire may be used
- Complete the responsibility questionnaire: up to three customers or contracts, and a financial institution reference sheet for each bank, with the bank section left blank
- Identify any exception to the solicitation terms and give the reasons; send your best price in the first quote
- Keep the quote valid for Government acceptance through March 1, 2027
- Send questions to the points of contact and the Contracting Officer by 1:00 PM on November 19, 2026
Current contractor
No incumbent is named; the performance work statement says the 5th Civil Engineer Squadron has historically received these services through service contracts.
Not in the notice text
- Several attachments were attached but not read: Quote Sheet FD winterization .xlsx, Helo 0-100_ Hose Line Fire_ Multi Control System_ Op AND Maint. Manuals.pdf and Minot O100 Manuals.pdf; the technical order TO 35E1-2-13-1 couldn't be read here, so check it on SAM.gov
- Parts of the solicitation, performance work statement, T-500 manual, hazardous waste plan and wage determination were left out; check them on SAM.gov
- The Government's estimate or budget for this requirement is not given
- The Quote Sheet's layout and line quantities beyond the schedule in the solicitation could not be checked
Notice details
Notice type, codes, versions and files
- Posted
- Nov 10, 2026
- Notice type
- Solicitation
- Office
- FA4528 5 CONS, Minot AFB, ND
- Product/service code
- J069 · Maint/Repair/Rebuild of Equipment – Training Aids and Devices
- Business type
- Equipment repair & maintenance (FedReady's grouping, from NAICS 811310)
- Attachments
Before you respond
- How to respond to a solicitation (8 steps)
- How to read a government solicitation
- How to price a government contract
- Set-aside contracts explained
Terms on this notice: Solicitation, Set-aside
Full notice text from SAM.gov
Similar open opportunities
- USCG Station Fire Island Attic VentsThe U.S. Coast Guard (Base Boston) wants a contractor to replace four attic exhaust fans and their controls at Station Fire Island in Babylon, NY (solicitation 30199PR270000005).
- Fire Extinguisher Inspection, Maintenance, Recharge, Repair, Hydrostatic TestingOpen to all businesses (no set-aside), solicitation W5S09H27QA991 asks for a single 5-year blanket purchase agreement (BPA: a standing deal where the buyer orders as needed…
- Fire Suppression System Maintenance andOnly service-disabled veteran-owned small businesses (SDVOSBs) can bid on solicitation 36C25027Q0078 from the Department of Veterans Affairs, Network Contracting Office 10.
- Vance AFB and Kegelman AAF Fire Extinguisher BPAThe Department of the Air Force (71st Flying Training Wing contracting office), solicitation FA302927Q0002, wants several firms on a multiple-award blanket purchase agreement…
- Dry-Type Fire Suppression SystemSources sought notice 36C26127Q0169 from the Department of Veterans Affairs (Network Contracting Office 21): the VA Palo Alto Health Care System wants to find firms that can…