Combined Synopsis/Solicitation
Inspection, maintenance and repair of cryogenic storage tanks.
Department of Defense · Department of the Navy
AI summary Beta
The Navy's Fleet Readiness Center East at MCAS Cherry Point, NC wants a contractor to inspect and maintain four cryogenic (super-cold liquid gas) storage tanks twice a year, plus do emergency inspections and repairs when needed. It is an unrestricted (no set-aside) firm-fixed-price award for a base year plus two option years, planned for 14 Jan 2026 to 13 Jan 2029. The dates in the SAM listing do not line up (see red flags), so confirm the due date before bidding.
Who can bid (7)
- Active SAM.gov registration
- CMMC Level 1 (self-assessment) status current in SPRS, with annual affirmation, for any contractor system that handles federal contract information From Solicitation - N6852026Q1007.pdf
- A CAGE code and a capability statement showing relevant expertise and certifications
Show all 7Show fewer
- Expert knowledge of cryogenic vessels and vacuums From Solicitation - N6852026Q1007.pdf
- Own helium mass-spectrometer leak detection equipment (sensitivity 1.0 x 10-9 or better) and vacuum pumps able to pull the tank annulus to 0.005 torr or less From Solicitation - N6852026Q1007.pdf
- Ability to TIG weld and silver braze for repairs, or to supervise such repairs From Solicitation - N6852026Q1007.pdf
- Work to American Vacuum Society (AVS) procedures and standards
How to submit: Preferred: email to the Primary Point of Contact listed in the SAM.gov notice. Contract Specialist is Carolyn Powell (carolyn.a.powell.civ@us.navy.mil); Contracting Officer is Adam Coombs. What to include is under Full summary below. Check the solicitation's instructions on SAM.gov.
Things to watch (8)
From the version posted Dec 15, 2025.
- Serious: Dates in the listing do not match. The notice was posted 15 Dec 2025 and says award is expected by 15 Jan 2026 with performance starting 14 Jan 2026, yet SAM.gov shows a response deadline of 19 Dec 2026, so the due date may be wrong and must be confirmed with the contracting office.
- Worth checking: No evaluation criteria stated. Section M (Evaluation Factors) is blank, so you cannot tell how the award will be decided; price is likely to matter most for this unrestricted buy.
- Worth checking: Specialized equipment and skills required. You need your own helium leak detection gear, high-vacuum pumps and welding/brazing capability, which is a high barrier for a general maintenance firm. From Solicitation - N6852026Q1007.pdf
Show all 8Show fewer
- Worth checking: Emergent repairs priced as not-to-exceed. Repair work is a priced option set at the accepted quote before work starts, so you carry the risk of pricing unknown tank repairs in advance and may not get the work. From Solicitation - N6852026Q1007.pdf
- Worth checking: Unrestricted competition. There is no small business set-aside, so you compete against large companies as well as small ones (the SF 1449 lists size standard $13,000,000 under NAICS 811310).
- Minor: Payment tied to service reports. Each visit needs a signed service report in the required format or payment is held. From Solicitation - N6852026Q1007.pdf
- Minor: Fixed schedule and weekday-only access. Visits must happen in January and July during weekday daytime hours only, with no overtime unless the Contracting Officer directs it. From Solicitation - N6852026Q1007.pdf
- Minor: Typos and mismatches in the solicitation. Pressure targets are inconsistent (0.005 vs 0.05 torr, both labeled 50 microns) and the option-year schedule dates are inconsistent, so ask for clarification before pricing.
Read from the notice and 1 attachment. Show which files.
- Solicitation - N6852026Q1007.pdf (read)
Full summary
What they want
- Twice-a-year (January and July) inspection and routine maintenance of 4 cryogenic tanks and their lines (2 argon, 2 nitrogen)
- Replace all relief valves more than 5 years past calibration or replacement on the first visit (about 6-12 valves; the Government supplies the valves)
- Keep tank vacuum annulus pressure at 0.05 torr (50 microns) or lower, using vacuum pumps and helium leak detection to find and fix leaks
- As-needed on-site emergency inspection with a written repair recommendation and pricing (option line)
- Emergent repairs of major components (valves, regulators, gauges) once the Government accepts the recommendation (option lines, up to 2 occurrences per year)
- Check in and out with the Equipment and Facilities Services Specialist, Bldg 84, on each visit
- Submit a signed service report after every visit; payment is withheld until it is received
- Contract type
- Single firm-fixed-price (FFP) award with Not-to-Exceed (NTE) line items; FAR Parts 12 and 13; FFP purchase order anticipated
- Period of performance
- Base year plus two option years: 14 Jan 2026 to 13 Jan 2029 (base 14 Jan 2026 to 13 Jan 2027; option years follow). FAR 52.217-9 extension clause caps total duration at three years
- Place of performance
- Fleet Readiness Center East (FRCE), Marine Corps Air Station Cherry Point, NC 28533 (tanks are in several buildings across the facility). Work hours 6:30 am to 3:00 pm, Monday to Friday
- Estimated value
- Not stated
- Offers due
- Dec 19, 2026, 4:00 PM Eastern
- How to submit
- Preferred: email to the Primary Point of Contact listed in the SAM.gov notice. Contract Specialist is Carolyn Powell (carolyn.a.powell.civ@us.navy.mil); Contracting Officer is Adam Coombs
What to include when you submit
- Include unit pricing for every line item on the Request for Quote (RFQ) N6852026Q1007 (SF 1449 form; offeror completes blocks 12, 17, 23, 24 and 30)
- Include vendor contact name, phone number and email address
- Include your company CAGE code
- Include a capability statement showing relevant expertise and certifications for cryogenic maintenance and repair
- Provide your CMMC unique identifier(s) from SPRS if you will handle federal contract information (Level 1 self-assessment is required)
- Complete the representations and certifications (Section K), or have them current in SAM.gov
Not in the notice text
- How the award will be decided: Section M (Evaluation Factors) is empty
- The exact quote due date and time: the SAM.gov deadline (19 Dec 2026) conflicts with the planned January 2026 start
- Estimated contract value or budget
- Whether there is a current contractor or a previous contract number
- Quantities and unit prices on the SF 1449 schedule are blank in the text, and the separate RFQ price form details are not shown
- Base access and security requirements for entering MCAS Cherry Point
- Whether a service contract wage determination applies (clause 52.222-41 is listed as an optional checkbox and no wage determination is attached)
- Page limits or format for the quote
More to check before you bid
- The AI summary also reads the notice as naming requirements:
- The AI summary's reading of the notice and its attachments says a bidder needs: CMMC certification. The summary's list is under Who can bid; check it in the notice before you bid.
Notice details
Notice type, codes, versions and files
- Posted
- Dec 15, 2025
- Notice type
- Combined Synopsis/Solicitation
- Office
- Fleet Readiness Center, Patuxent River, MD
- Product/service code
- J036 · Maint/Repair/Rebuild of Equipment – Special Industry Machinery
- Business type
- Equipment repair & maintenance (FedReady's grouping, from NAICS 811310)
- Attachments
Before you respond
- How to respond to a solicitation (8 steps)
- How to read a government solicitation
- How to price a government contract
Terms on this notice: Solicitation
Full notice text from SAM.gov
Similar open opportunities
- Fire Extinguisher Inspection, Maintenance, Recharge, Repair, Hydrostatic TestingOpen to all businesses (no set-aside), solicitation W5S09H27QA991 asks for a single 5-year blanket purchase agreement (BPA: a standing deal where the buyer orders as needed…
- Halon Bottle InspectionOnly small businesses can bid on solicitation W50S6Y27RA002 from the Florida Air National Guard (125th unit), a total small business set-aside.
- CTX VAMC Maintenance, Calibration, Inspection, and Testing of the Electrical Power Distribution SystemSolicitation 36C25727Q0089: only service-disabled veteran-owned small businesses (SDVOSBs) listed in VA's Vendor Information Pages (VIP) can bid.
- Maintenance, Repair, and Inspection of Hoists in the Kaiserslautern Military Community (KMC)The U.S. Air Force (786 CES, Ramstein Air Base, Germany) wants a contractor to maintain, repair and inspect the real-property hoists and cranes across the Kaiserslautern Military…
- Initial Restoration, Testing, and Continuous Sustainment of ASG-J Owned 6K SCAT TanksSources sought (solicitation number ASG-JOCS1119): the Army is asking firms for capability statements and rough price estimates to restore, test and maintain 6,000-gallon…