Combined Synopsis/Solicitation
Fire Alarm-Fire Suppression Services for the VA Salt Lake City, Utah Medical Center
Department of Veterans Affairs · Sol. 36C25925Q0740
AI summary Beta
Some details weren't available to this summary, so it may miss requirements. Check the attachments on SAM.gov.
The VA Network Contracting Office 19 wants one contractor to monitor, inspect, test, maintain and repair the fire alarm and fire suppression systems at the VA Salt Lake City Health Care System (George E. Wahlen VA Medical Center, 29 buildings) in Salt Lake City, Utah. It is a firm-fixed-price contract for a base year starting 11/01/2026 plus four option years, open to all businesses with no set-aside. Bidders need a Siemens authorization letter and Utah State Fire Marshal licenses and technician certificates, and the full Statement of Work was not in the files provided.
Watch out for
- Siemens authorization and state licenses required. Without a Siemens authorization letter and Utah fire marshal licenses and certified technicians, a small business cannot submit a responsive quote.
Offeror must submit proof of their authorization to perform the services and access to the current Siemens System.
- All-or-nothing award. You must price and be able to perform the whole requirement; you cannot bid on part of it.
Any award made as a result of this solicitation will be made on an All or Nothing Basis.
- Missing building and device data. The Government gives device counts for only some buildings, so you must work out quantities yourself and carry the pricing risk.
The awarded contractor will need to determine quantities for the remaining buildings.
- Damper testing with poor records. All fire and smoke dampers are to be tested in the base year, the last data is poor, and no current inventory exists, so the amount of work is uncertain.
A current inventory is not avaible at this time
- Extra costs fall on the contractor. Travel is not paid, and fire watch, lifts and scaffolding, and wall or ceiling access for damper tests are the contractor's job, which must be built into a fixed price.
Response: Government will not pay for travel.
- Fast on-site emergency response. After-hours emergencies need someone physically on site within two hours, which is hard for a small firm without local staff.
Response: On-site
- Many amendments and shifting dates. The solicitation has gone through at least seven amendments with repeated due-date extensions and some conflicting details, so read the newest versions and confirm the final due date with the contract specialist.
** HOUR & DATE for Receipt of Offers is EXTENDED to: 10-20-2026 12:00 CDT
- Site visits already held. The scheduled site visits (August and September 2026) are past, so you may not be able to inspect the buildings before quoting.
Read from the notice and 12 attachments. 17 not read in full.
- Solicitation Site Visit Information.docx
- Solicitation Site Visit Information Amendment 0004.docx
- RFQ Amendment 36C25925Q0740 0004.docx
- Solicitation Site Visit Information 36C25925Q0740 02.docx
- 36C25925Q0740 0007.docx
- 36C25925Q0740 0007_1.docx
- 36C25925Q0740 Responses to Questions.docx
- 36C25925Q0740 0006.docx
- 36C25925Q0740 0006_1.docx
- 36C25925Q0740 0005.docx
- 36C25925Q0740 0005_1.docx
- 36C25925Q0740 0004_1.docx
- Answers to Solicitation Questions Amendment 0004.docx: too large
- Answers to Solicitation Questions 2 of 2.docx: too large
- 36C25925Q0740 0003_1.docx: over the file limit for one brief
- 36C25925Q0740 0002.docx: over the file limit for one brief
- 36C25925Q0740 0001.docx: over the file limit for one brief
- 36C25925Q0740_2.docx: over the file limit for one brief
- P09 - Final SOW Amendment 0004.docx: over the file limit for one brief
- P09 - Final SOW - 04292026.docx: over the file limit for one brief
- P09- Final SOW.docx: over the file limit for one brief
- VA SLCHCS Fire and Smoke Damper List Amendment 0004.xlsx: spreadsheet: not read yet
- TJC Equipment Summary List Amendment 0004.xlsx: spreadsheet: not read yet
- SLC VAMC Building 14 Damper Locations.pdf: over the file limit for one brief
- SLC VAMC Building 3 Damper Locations.pdf: over the file limit for one brief
- SLC VAMC Building 1 Damper Locations.pdf: over the file limit for one brief
- 52.222-90 Addressing DEI Discrimination by Federal Contractors.docx: over the file limit for one brief
- TJC Equipment Summary List.xlsx: spreadsheet: not read yet
- VAMC Salt Lake City Fire and Smoke Damper List.xlsx: spreadsheet: not read yet
Full brief
What they want
- 24/7 monitoring of fire alarm and fire suppression systems (12 months per year; 17 accounts required at contract start)
- Quarterly (4), semi-annual (2) and annual (1) testing and maintenance per year, following the Statement of Work and NFPA standards
- Emergency unscheduled repair labor: 24 hours during normal business hours and 8 hours after hours per year, with on-site response (4 hours in business hours, 2 hours after hours)
- Provide a $50,000 per year allowance line for repair, replacement or modification parts
- Test fire and smoke dampers in the base year and include required NFPA 25 and NFPA 96 work (sprinkler, standpipe and kitchen hood systems)
- Hold your own Siemens programming license and provide fire watch, access equipment and ceiling/wall access for testing
- Contract type
- Firm-fixed-price; combined synopsis/solicitation (RFQ) under commercial procedures; award is all-or-nothing
- Period of performance
- Base year 11/01/2026 to 10/31/2027 plus four option years through 10/31/2031 (also 52.217-8 extension up to 6 months and 52.217-9 term limit of 5 years total)
- Place of performance
- VA Salt Lake City Health Care System, George E. Wahlen VA Medical Center, 500 S Foothill Blvd, Salt Lake City, UT 84148 (29 buildings per the Q&A)
- Estimated value
- Not stated. Each year has a $50,000.00 allowance line for repair parts; all other lines are left for the bidder to price.
- How they'll choose
- Best value (most advantageous to the Government, price and other factors considered), using comparative analysis; quotes that fall short on technical capability are not selected regardless of price
- Offers due
- 10/20/2026, 12:00 PM Central (amendment 0007 writes it as both CDT and CST)
- How to submit
- Email only, to thomas.parsons2@va.gov (the amendment 0004 RFQ also lists john.cheng2@va.gov); 4MB email limit; no hand-carried or faxed quotes
- Page limits
- No page count is stated in the text read; at most 3 past performance references
What they'll judge offers on
- Factor I: Technical capability or quality offered to meet the requirement
- Factor II: Price (total of all line items including all options)
- Factor III: Past performance (relevance and how well you performed)
What to include when you submit
- Submit three volumes: (I) Technical capability, (II) Price, (III) Past Performance; a quote missing a volume may be treated as nonresponsive
- Price the base year and all four option years on the price schedule, and state whether items are on a GWAC, GSA MAS or VA-wide contract
- The RFQ must be completed in full, signed and dated
- Include a Siemens authorization letter naming your company, plus your communication procedures for notifying the customer and the fire department
- Include proof of Utah State Fire Marshal Concern License Class H1 and H2 and your technicians' sprinkler and fire alarm inspecting and testing certificates
- Past performance: up to three recent (within 5 years) and relevant efforts, with CPARS if available, otherwise contract numbers, values, contacts and a description of the work
- Acknowledge all amendments (the latest in the text is 0007)
- Questions were due 08/28/2026 and will not be accepted now
You must have
- Open to all businesses; no set-aside (but the clause list also shows the small business set-aside clause checked, so confirm)
This solicitation is open market unrestricted.
- Authorization letter from Siemens proving the bidder can work on the current Siemens system
Offeror must submit proof of their authorization to perform the services and access to the current Siemens System.
- Active Utah State Fire Marshal Concern License Class H1 and H2
Offeror must provide proof of an active Utah State Fire Marshal
- Technicians must hold active Utah State Fire Marshal sprinkler and fire alarm inspecting and testing certificates
Offeror must provide proof of active certification of their designated technician(s)
- Contractor must hold its own Siemens programming software license
The contractor must hold its own Siemens programming license.
- Active SAM registration and compliance with VA personnel vetting (PIV) rules; the VA says it will sponsor PIV credentials for subcontractor technicians
Current contractor
Not named. The Q&A mentions an existing vendor whose monitoring service holds the current accounts and a current bridge contract, so this is a recompete or follow-on of existing service.
Not in the notice text
- The full Statement of Work (P09 Final SOW Amendment 0004) was not provided, so detailed scope, building list, inspection frequencies and reporting duties are not confirmed
- Device quantities and damper inventories for most buildings (TJC Equipment Summary List and damper lists were not provided)
- The earlier question-and-answer documents (Answers to Solicitation Questions) and amendments 0001 to 0003, which may change terms
- Whether the small business set-aside clause shown in the clause list applies despite the 'open market unrestricted' statement
- The service contract wage determination for Salt Lake City, if one applies
- Estimated contract value or budget (only the $50,000 yearly parts allowance is stated)
FedReady checks notices like this against your business profile, tracks deadlines, and alerts you to new matches. Creating an account is free.
Key facts
- Response due
- Oct 20, 2026, 5:00 PM UTC
- Posted
- Sep 18, 2026
- Notice type
- Combined Synopsis/Solicitation
- Solicitation
- 36C25925Q0740
- Agency
- Department of Veterans Affairs
- Office
- Network Contract Office 19 (36C259)
- NAICS
- 561621
- Product/service code
- J012
- Business type
- Security & guard services
- Place of performance
- Salt Lake City, UT, 84148
- Contracting contact
- Thomas Parsonsthomas.parsons2@va.gov918-577-3532
- Versions
- 10 (amended since first posted)
Full notice text from SAM.gov
Similar open opportunities
- DRAFT RFP - Global Unified Airbase Readiness and Defense (GUARD) IDIQ - Force Protection DivisionThe Air Force Life Cycle Management Center (Force Protection Division, Hanscom AFB, MA) posted a draft RFP as a request for information on the planned GUARD IDIQ, a…
- Amendment 0002 Lenel OnGuard Door Access Control System UpgradeThe Army (MICC Fort Riley) wants a small business to replace the badge-and-door access system at Irwin Army Community Hospital, Fort Riley, KS, with the brand-name Lenel OnGuard…
- MEDECO INTELLIGENT KEY HIGH-SECURITY LOCK SYSTEMThe VA (Network Contracting Office 21, for VA Northern California Health Care System in Mather, CA) plans to buy MEDECO Intelligent Key high-security lock cores, key fobs,…
- FIRE & LIFE SAFETY SYSTEM PM&R SERVICES HARRY S TRUMAN VA MEDICAL CENTER COLUMBIA, MISSOURIThe VA's Network Contracting Office 15 is doing market research (a Sources Sought) for maintenance, inspection and testing of fire and life safety systems at the Harry S. Truman…
- Advanced Programs-OMN-Security System MaintenanceThe Navy's NAWC Training Systems Division in Orlando, FL is running a Request for Information (market research, not a solicitation) for service, repair, preventive maintenance…