Solicitation
Sewage Ejector and Line Assessment
Dept of Defense · Dept of the Army · Sol. W912BV26QA069
Due in 24 days
AI summary Beta
Some details are in the notice's attachments, which this summary didn't read. Check the attachments on SAM.gov.
The Army Corps of Engineers (Tulsa District) wants a contractor to locate, inspect and modify an unmapped 700 to 800 foot sewer line and its distribution box, and report back with findings and cost estimates. The notice text gives only the scope of work; the place of work and other terms are not stated. Offers are due October 28, 2026.
Watch out for
- Government must be present at all site inspections. You will need to schedule every inspection around Government staff, which can slow the work.
with mandatory Government presence during all site inspections
- Unmapped underground line. The line's location is not known, so finding it is part of the job and could take more effort than expected.
locate, inspect, and modify an unmapped 700 to 800 foot concrete-encased four inch cast iron sewer line
- Open-ended findings report. You must price and write up corrective actions for lateral lines you have not yet seen.
any recommended corrective actions for the lateral lines must be delivered via a detailed findings report with comprehensive labor and material cost estimates
Read from the notice text only.
Full brief
What they want
- Locate and inspect an unmapped 700 to 800 foot concrete-encased four inch cast iron sewer line
- Install concrete-encased Schedule 40 PVC double-Y clean-outs every 300 feet
- Expose and inspect the distribution box and its 2009 leach field connections
- Extend the box cover with a riser and a structural cover rated for three ton vehicle traffic
- Protect the box with four concrete-encased steel safety-yellow bollards
- Record all changes as Red Line As-Builts on the reference drawing
- Deliver a findings report with labor and material cost estimates for any corrective actions on the lateral lines
- Offers due
- 2026-10-28 at 12:00 PM (UTC-06:00), per the SAM.gov response deadline field
Not in the notice text
- Where the work is (place of performance is blank)
- Contract type and how the award will be decided
- Time allowed to finish the work
- How to submit a quote and what to include
- Whether a site visit is offered
- Any licenses, bonding or insurance requirements
- Estimated value
Is this a fit for your business?
Create a free accountFedReady checks notices like this against your business profile, tracks deadlines, and alerts you to new matches. Creating an account is free.
Key facts
- Response due
- Oct 28, 2026, 6:00 PM UTC
- Posted
- Sep 28, 2026
- Notice type
- Solicitation
- Solicitation
- W912BV26QA069
- Agency
- Dept of Defense · Dept of the Army
- Office
- W076 Endist Tulsa
- NAICS
- 237110
- Product/service code
- J045
- Business type
- Energy, fuel & utilities
- Contracting contact
- CALEB DAVIScaleb.a.davis@usace.army.mil9186690237
- Versions
- 4 (amended since first posted)
Full notice text from SAM.gov
This scope of work requires the contractor to locate, inspect, and modify an unmapped 700 to 800 foot concrete-encased four inch cast iron sewer line and its associated distribution box, with mandatory Government presence during all site inspections. Key tasks include installing concrete-encased Schedule 40 PVC double-Y clean-outs every 300 feet, exposing and inspecting the distribution box and its 2009 leach field connections, and extending the box cover using a riser and structural cover rated for three ton vehicle traffic protected by four concrete-encased steel safety-yellow bollards. All physical, material, and dimensional adjustments must be documented as Red Line As-Builts on the reference drawing, and any recommended corrective actions for the lateral lines must be delivered via a detailed findings report with comprehensive labor and material cost estimates.